Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Lennox Hearth, modell B-ENC5304VDE

Hersteller: Lennox Hearth
Dateigröße: 3.72 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Pull the door diagonally to the left, away from the fireplace. Once the control compartment door has been removed, the modesty panel can be removed as follows: slide the modesty panel forward until it contacts the cabinet bottom panel, then lift straight up and tilt forward. Remove the modesty panel carefully, so that none of the wires become loose or disconnected. Now complete access to the gas control valve and its related controls is attainable. To ease door closure, depress the catches to place them in their retracted position until they stay there, then close the door. Operation of millivolt and electronic gas control systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Refer toFigure 1 for access to the gas control valve. Millivolt appliances will be fitted with the gas control valve shown in Figure 2. Appliances with electronic systems will be fitted with the electronic valve shown inFigure 3. Familiarize yourself with the gas control valve that your appliance uses. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 3 Honeywell Electronic Gas Valve Figure 2 Note: The piezo ignitor is located on the modesty panel - refer to Figure 1. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alternately, while the appliance is in operation. Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob located on the front of the valve (refer to Figure 2). (An extension is provided to this knob so that the adjustment may be made at the modesty panel.) 2. When lit for the first time, this appliance will emit a slight odor for an hour or two. This is due to the “burn-in” of internal paints and lubricants used in the manufacturing process. HI LOW TPTH TP TH PILOT PILOTON it OFF Variable Flame Height Adjustment Manifold Pressure Port Inlet Pressure Port Main Gas Control Knob IN OUT SIT Millivolt Gas Valve ON/OFF Switch Electronic Gas Control Valve Inlet Pressure Port Manifold Pressure PortOFFINPSI ONCONTROL IGNITER Millivolt Appliances - To light millivolt appliances refer to the detailed lighting instructions found on page 11 (English) and page 12(French). Millivolt ap- pliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Millivolt appliances are fitted with an ON/OFF Rocker Switch for appliance ON/OFF control. See Figure 1for its location. Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions. If your millivolt appliance is equipped with an optional remote wall switch or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall switch or remote control. Electronic Appliances - To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 13 and 14of these instructions respectively. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Electronic appliances are fitted with an ON/ OFF Rocker Switch for appliance ON/OFF control. See Figure 1for its location. Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions. If your electronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control. 3. Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and circulating air passageways of the appliance be kept clean and clear of obstruction of venting and combustion air. 4. Always turn off gas to the pilot (millivolt appliances) before cleaning. Before re-lighting, refer to the lighting instructions in this manual. Instructions are also found on a pullout panel located on the floor of the appliance. 5. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids. 6. Remember, Millivolt appliances have a continuous burning pilot flame. Exercise caution when using products with combustible vapors. Glass Cleaning It will be necessary to clean the glass periodically. During start-up it is normal for condensation to form on the inside of the glass. This can cause lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recomm...

Dieses Handbuch ist für folgende Modelle:
Kamine - B-ENC0353VDE (3.72 mb)
Kamine - B-ENC0454VDE (3.72 mb)
Kamine - B-MNC0353VDE (3.72 mb)
Kamine - B-MNC0454VDE (3.72 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien