Hersteller: Cadet
Dateigröße: 209.41 kb
Dateiname:
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If replacing an existing heater check the labels of the old heater and replace using same voltage. Hooking a 240 volt heater to a 120 volt power supply will drastically reduce the heater’s output. Hooking a 120 volt heater to a 240 volt power supply will destroy the heater. LEVEL The Softheat baseboard heater must be properly leveled when installed, in order for the heating chamber to function properly. INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS STEP 1: Mount Heater to Wall 1. Locate wall studs closest to supply wires and position heater (See Figure 1). NOTE: Wire connection is from left side only on standard models. SUPPLY STUDS FLOOR FINISHED WALL Figure 1 2. Carefully remove front cover from heater by lifting cover up from the bottom, and then outwards. Set aside. 3. Remove wiring compartment cover, held by one screw, from side you wish to wire. (Figure 2). 4. Remove slotted knockout closest to the supply wires and install a strain relief connector. 5. Pull supply wires through the connector and secure, leaving 6 inch wire leads for later use. 6. NOTE: If you will be installing a heater mounted EBKN thermostat, you should do so now before mounting your baseboard to the wall. See your EBKN thermostat Owner’s Guide for instructions. 7. Position the heater and fasten one end of heater to wall stud with screw in safe drill area as shown in Figure 3. Before fastening to wall stud at other end, place level across top of heater and make sure heater is level. (Figure 4). Figure 2 Left-end wiring shown Figure 3 Drill areas Left-end wiring shown Figure 4 Checking with level STEP 2: Wiring Provisions / Wiring This heating unit is designed for permanent installation. All wiring should be routed in compliance with the National Electrical Code and all local codes, where applicable. A maximum of No. 10 AWG wire may be used with this heater. All wiring should be planned and run before heating units are set in place. Standard units are wired from left end of the heater only. (See Figure 5 for internal heater wiring). When wiring unit through rear, remove knock out and place heater on wall. Mark knockout location on wall. When running conduit or cable to unit through flooring and knock out in bottom of wiring compartment, measure 1-1/2” (38mm) from wall and 2” (51mm) from left end of unit. Cut a 7/8” (22mm) hole in floor centered on the measured location (See Figure 6). Connect the grounding lead to the green ground screw (provided), using a connector. (See Figure 5). Protect electrical supply from kinks, sharp objects, oil, grease, hot surfaces or chemicals. *Distance measured from finished floor surface. Figure 5 Figure 6 Left-end wiring (standard) Ground Screw READ ALL INSTRUCTIONS AND SAFETY INFORMATION. CAUTION - HighTemperature, KeepElectrical Cords, Drapes, And OtherFurnishings AwayFrom Heater WARNING! RISK OF ELECTRICAL SHOCK. TURN OFF ALL POWER AT THE ELECTRICAL PANEL BOARD SUPPLYING POWER TO THE HEATER BEFORE DOING ANY ELECTRICAL WIRING. WARN...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - SOFTHEAT EBHN1000-8 (209.41 kb)
elektrische Heizungen - SOFTHEAT EBHN1500-8 (209.41 kb)
elektrische Heizungen - SOFTHEAT EBHN500 (209.41 kb)
elektrische Heizungen - SOFTHEAT EBHN750 (209.41 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien