Login:
Stimmen - 5, Durchschnittliche Bewertung: 4 ( )

Anleitung Monessen Hearth, modell TPB30

Hersteller: Monessen Hearth
Dateigröße: 6.79 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


BURNER ASSEMBLY Item Qty TPB18 TPB24 TPB30 Natural Propane Natural Propane Natural Propane 1 Piezo Ignitor 1 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 2 Piezo Wire 1 00K0632 00K0632 00K0632 00K0632 00K0632 00K0632 3 Burner 1 70D0104 70D0104 70D0010 70D0010 70D0010 70D0010 4 Control Valve 1 14D0467 14D0468 14D0467 14D0468 14D0467 14D0468 5 Injector 1 58D0051 58D0052 70D0064 57D0680 70D0064 57D0680 6 ODS Pilot Assembly 1 14D0473 14D0477 14D0473 14D0477 14D0473 14D0477 7 On/Off Switch 1 32D0232 32D0232 32D0232 32D0232 32D0232 32D0232 8 Pilot Regulator 1 14D0469 — 14D0469 — 14D0469 — ACCESSORIES SOLD SEPARATELY Description Part Number Flex Connector Flexcon 30 Wall Switch and Wire MVWS Wall Thermostat Kit WT On/Off Remote RCB, RCM, WMTD Thermostat Remote RCST, RCT, WWTD Remote Receiver Cover Ember RRCE Remote Receiver Cover Metal RRCM On/Off Touch Light Remote TLM Remote Touch Light T-stat TLT Cast Iron Gate and Andirons CIGA Log Switch with Wires ELSK Riser Kit TP24RK TPB18-RW for 18" burner Rock Wool Bag TPB24-RW for 24" & 30" burner 70D0004 37 REPLACEMENT PARTS LIST REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER. CHARRED TIMBER LOGS Item Description Qty CTCL18 CTCL24 CTCL30 1 Rear Log 1 70D0121 70D0031 70D0221 2 Right Base Log 1 70D0122 70D0032 70D0222 3 Left Front Base Log 1 70D0123 70D0033 70D0223 4 Right Front Log 1 70D0127 70D0037 70D0227 5 Left Top Log 1 70D0139 70D0065 70D0229 6 Right Top Log 1 70D0124 70D0034 70D0224 #1#2#4#3#6Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. WARNING 38 70D0004 NOTES 70D0004 39 MASSACHUSETTS RESIDENTS ONLY: PLEASE READ AND FOLLOW THESE SPECIAL REQUIREMENTS NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence. Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position. In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve. NOTE REGARDING VENT FREE PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve. CARBON MONOXIDE DETECTOR REQUIREMENTS (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent fl oor level. b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. 40 70D0004 SPECIAL REQUIREMENTS CONTINUED 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the ex...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - TPB18 (6.79 mb)
elektrische Heizungen - TPB24 (6.79 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien