Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Alpha Industries, modell 3000

Hersteller: Alpha Industries
Dateigröße: 1023.25 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The first parameter, “O/P Volt Set” is displayed on the LCD (Figure 3.1). 2 Press FUNC to scroll through the parameters until “Battery Test” appears. 3 Press the ENTER button. When the LCD shows “Test?” press ENTER. The test starts and the LCD shows “Battery Test.” 4 After the test, the unit resumes line mode and the LCD shows “Line Mode.” If a fault is found, the FAULT LED is on. Do troubleshooting as described in Section 3.5. Self Test Finished 3.4 Changing the Parameters You can change the unit’s factory set parameters to suit your local conditions (Figure 3.1). Any changes should be done after the unit is started, but before the loads are turned on. Procedure TIP: If no buttons are pushed for 10 seconds, the LCD exits this menu and displays the operating mode. 1 Press the FUNC button for 5 seconds. The first parameter, “O/P Volt Set” is displayed on the LCD. 2 Press FUNC to scroll through the parameters (Figure 3.1). 3 Press ENTER to select a parameter.. Alpha Technologies 3 Operation 18 3.4 Setting the Parameters (Continued) 4 Press FUNC to display the selections. Press ENTER to select the selection. If the LCD shows “Save?” press ENTER to set the unit to the new parameter. Parameter Changing Finished Parameter LCD Shows Description Available Selections Factory Default Output Voltage O/P Volt Set Select the nominal output voltage 208/220/230/240 VAC 230 VAC 100/110/115/120/127 VAC 120 VAC Input Frequency I/P Freq Set Select the input frequency range when UPS goes into free run mode ±2%, ±5%, ±7% ±5% Input/Bypass Voltage I/P Bypass Set Select the input voltage range when bypass is available ±10%, +10/-15%, +15/-20% +10/-15% Free Run Mode (See Note 4) Free Run Set Select if the UPS can operate in free run mode (unsynchronized) ON/OFF ON Bypass Enable/Disable at Free Run mode (See Note 4) Bypass Disable If enable is selected, the UPS can go to bypass when unsynchronized Disable/Enable Disable HE Mode Setting (See Note 1) HE Mode Set Select if the UPS can run in high efficiency mode ON/OFF OFF Force Manual Bypass Manual Bypass FOR SERVICING ONLY * Management of Load Groups Outlet Setting You can turn the two load groups on and off from the front panel 1 ON & 2 ON 1 OFF & 2 ON 1 OFF & 2 OFF 1 ON & 2 OFF 1 ON & 2 ON Battery Test Battery Test Tests if the battery can provide backup power Silence Function Silence Set Turn the audible alarm on or off ON/OFF OFF Number of External Battery Packs Batt Cabinet Set This lets the UPS predict the battery backup time 0 (if no cabinets are used) 1 (one cabinet used) 2 (two cabinets are used) 0 Site Wiring Alarm (See Note 3) Sit Fault Set This enables or disables the site wiring alarm Disable/Enable Disable Select Language Language Select the UPS's language English, German, French, Spanish, Italian English Set Generator Mode (See Note 2) Generator Set UPS in generator mode** ON/OFF OFF Set RS-232 Communication RS232 Control Set the UPS's RS-232 communication Disable/Enable Enable * For the unit’s and the power management software to operate properly, the manual bypass should be set to OFF. This feature is meant to be used with an external maintenance bypass switch. ** Turn the unit off and restart after changing this parameter. Figure 3.1 Parameters Alpha Technologies 19 3 Operation 3.4 Setting the Parameters (Continued) Notes: 1) HE Mode Set: This is used to set if the unit sends the line power through double conversion and then to the loads (HE Mode:OFF) or straight through to the loads (HE Mode:ON). 2) Set Generator Mode: This widens the input parameters so the unit can be used with a generator. 3) Site Wiring Alarm: This tells you if the line’s ground and neutral wiring is reversed. 4) Free Run Mode, Bypass Enable/Disable at Free Run Mode: These two parameters work together to control the unit’s input voltage or frequency windows. The available combinations are: Combination Result Free Run: ON Bypass: DISABLED (Factory Default) Input window is: 45-65 Hz (Automatic frequency sensing) 96-138 VAC (60 Hz) 184-265 VAC (50 Hz) Free Run: ON Bypass: ENABLED Input voltage window is: ±10%, +10%/-15% or +15/-20% VAC (operator set) Free Run: OFF (Bypass is automatically turned off) Input frequency window is: ±2%, ±5% or ±7% Hz (operator set) Figure 3.2 Free Run/Bypass Combination Table Alpha Technologies 3 Operation 20 3.5 Troubleshooting When the fault LED turns on or the audibile alarm is heard, perform troubleshooting as shown in the table below. LCD Shows Audible Alarm * Description Action Output Overload 2 beeps per second The UPS is overloaded. It is operating in Bypass mode. Shut down loads, starting with the least important. Battery Test No beeps The UPS is performing a battery test. None. The UPS will return to normal operation when the test is done. Over-Charge Constant beeping The batteries are overcharged. Turn off the loads and the UPS. Contact Alpha Technologies. Low Battery 2 beeps every 5 seconds The UPS is operating on battery power and the batteries are almost ...

Dieses Handbuch ist für folgende Modelle:
Netzteile - 1000 (1023.25 kb)
Netzteile - 1500 (1023.25 kb)
Netzteile - 2000 (1023.25 kb)
Netzteile - 700 (1023.25 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien