Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Alpha Industries, modell 700

Hersteller: Alpha Industries
Dateigröße: 1023.25 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Only qualified personnel should change them. Procedure WARNING: Do not replace the batteries when the ON-BATT LED is on. 1 Enable the manual bypass (Section 3.4). 2 Pop off and remove the front cover.. 3 Unscrew and remove the battery cover. 4 Remove the battery cartridge from the unit. Take note of the battery configuration and wiring. 5 Replace the batteries with any of the qualified batteries listed in Figure 3.4. 6 Push the cartridge with the new batteries back into the unit. 7 Reinstall the battery cover.. 8 Reinstall the front cover.. 9 Disable the manual bypass (Section 3.4) 10 Do a self test (Section 3.3). Battery Replacement Finished Model Battery Type # of Batteries Manufacturer Pinnacle Plus 700 12V, 7.2 AH 2 CSB-GP1272 Panasonic LC-R127R2P Hitachi HV7-12F2 Pinnacle Plus 1000 3 Pinnacle Plus 2000 6 Pinnacle Plus 1500 12V, 9.0 AH 3 CSB HR1234W F2 Pinnacle Plus 3000 6 Figure 3.4 Qualified Replacement Batteries 3 Operation 22 3.7 Specifications 700/700RM 1000/1000RM 1500/1500RM 2000/2000RM 3000/3000RM Electrical Output VA (W) 700 (490) 1000 (700) 1500 (1050) 2000 (1400) 3000 (2100) Input/Output Voltage (VAC) 100 / 110 / 115 / 120 / 127 Input Current (Max); Amps, 120 VAC Units 10 12 15 20 30 Input Frequency (Hz) 50 / 60 (Auto Sensing) Output Frequency (Hz) 50 / 60 ± 0.5% Transfer Time (mSec) 0 Crest Factor 3:1 Harmonic Distortion < 3% of THD at linear load Output Waveform Sine UPS Design Technology On-Line, fully digitized microprocessor controlled High Efficiency Mode (AC to DC) >95% Overload Recovery Auto transfer to UPS Surge Protection 120V: IEEE C 62.41 / 230V: IEEE 61000-4-5 Level 3 Overload Protection 125% for 1 minute and 150% for 10 seconds Short Circuit Protection UPS output automatically cut off or input fuse/circuit breaker protection Battery Type Sealed, maintenance free lead acid Battery Protection Cut off when battery is low to prevent drainage Battery Recharge Time 4 hours to 90% of capacity Communication RS-232 serial port / USB port / built-in SNMP slot Mechanical Tower Dimensions W x D x H; in (mm) 6.0 x 16.5 x 9.4 (152 x 420 x 238) 8.9 x 16.7 x 14.2 (225 x 425 x 360) Tower Weight; lb (kg) 29.7 (13.5) 35.6 (16.2) 37.4 (17.0) 68.4 (31.1) 72.6 (33.0) Rack Mount Dimensions W x D x H; in (mm) 16.9 x 16.7 x 3.3 (428 x 425 x 84) (2RU) 16.9 x 25.0 x 3.3 (428 x 635 x 84) (2RU) Rack Mount Weight; lb (kg) 32.1 (14.6) 37.6 (17.1) 39.8 (18.1) 69.5 (31.6) 71.5 (32.5) Input Connectors NEMA 5-15P NEMA L5-20P NEMA L5-30P Environmental Operating Temperature °F(°C) 32-104 (0-40) Storage Temperature °F(°C) -4-122 (-20-50) Altitude (Max); ft (m) 15000 (3500) Audible Noise @1 m < 40 dBA Humidity up to 95%, non-condensing Conformance Safety (Designed to Meet) UL 1778 / CSA EMC (EMS / EMI) IEC 61000-4 / FCC Part 15 Class B / CISPR 22 Alpha Technologies 23 Warranty Alpha Technologies warrants its equipment to be free of manufacturing defects in material and workmanship for a period of 36 months from the date of manufacture. The liability of Alpha Technologies under this warranty is solely limited to repairing, replacing, or issuing credit for such equipment (at the discretion of Alpha Technologies), provided that: 1. Alpha Technologies’ Customer Service Department is promptly notified, by facsimile or telephone, that a failure or defect has occurred. 2. Alpha Technologies’ Customer Service Department issues a Return Materials Authorization (RMA) number, and designates the service location. The RMA must be clearly marked on the outside of the shipping container. 3. Purchaser is responsible for all in-bound shipping and handling charges (COD and freight collect will not be accepted without prior approval from Alpha Technologies); Alpha Technologies will pay out-bound surface shipping charges for return of repaired equipment. 4. A satisfactory examination of the returned unit by Alpha Technologies’ Service personnel shall disclose that defects have not been caused by misuse, neglect, improper installation, repair, alteration, or accident, or failure to follow instructions furnished by Alpha Technologies. If Alpha Technologies’ Service personnel determine that the unit has been damaged due to one of these causes, or if the unit is free of defects, a handling or repair fee may be assessed prior to returning the unit. WITH RESPECT TO BATTERIES, PERIPHERAL DEVICES, ATTACHMENTS OR APPARATUS NOT MANUFACTURED BY ALPHA TECHNOLOGIES, ALPHA WILL ASSIGN TO THE PURCHASER ITS RIGHTS UNDER THE ORIGINAL MANUFACTURER’S WARRANTY OF SUCH BATTERIES, PERIPHERAL DEVICES, ATTACHMENTS OR APPARATUS, BUT OFFERS NO ADDITIONAL WARRANTIES IN CONNECTION THEREWITH. THIS LIMITED 36-MONTH WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO CASE SHALL ALPHA TECHNOLOGIES BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING WITHOUT LIMITATION ANY CLAIM FOR LOST PROFITS OR REVENUES, EVEN ...

Dieses Handbuch ist für folgende Modelle:
Netzteile - 1000 (1023.25 kb)
Netzteile - 1500 (1023.25 kb)
Netzteile - 2000 (1023.25 kb)
Netzteile - 3000 (1023.25 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien