Anleitung Linear, modell SLC

Hersteller: Linear
Dateigröße: 949.83 kb
Dateiname: SL_APeX_Series.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Stagger Mode The Stagger Mode function determines if the operator has a delayed open or a delayed close. In dual swing gate installations, typically one operator is programmed for delayed open, and the other operator is programmed for delayed close. • Stagger Delay Time The Stagger Time sets the length of the delay for the Stagger Mode. See Pages 11, 13, & 14 for details on these three dual gate programming functions. Set the following parameters in each gate operator individually in a single gate mode before connecting the network cable and operating in dual gate mode. 1. Open and Close Limit settings 2. Open and Closed direction inherent entrapment protection (OC & CC) After these parameters have been set, and each operator has been tested independently and is functioning correctly in single gate mode, then set BOTH operators to dual gate (dg) in the Paired Mode setup step under Basic Programming steps. OPERATOR #1 OPERATOR #2 USE BELDEN 8760 TWISTED PAIRSHIELDED CABLE OR EQUIVALENT SHIELD CONNECT SHIELD WIRE AT BOTH ENDSDUAL GATE COMM LINK WIRINGCONNECT C - C B -BA - A SHIELD Figure 12. COMM LINK Wiring SLR • SLC • SLD Slide Gate Operator Installation Guide - 25 - 227968 Revision X19 8-11-2011 Gate Operation Open Button Opens the gate. If the Controller is programmed to stop opening the gate at mid-travel, a constant press of the OPEN button will override the Mid-travel Stop and completely open the gate. If the Auto Close Timer is set, it will be suspended until the OPEN button is released. Close Button Closes the gate if the gate is open. Also closes the gate if the gate is in the process of opening. Stop Button Stops the gate from opening or closing at any time. Single Input Opens the gate if it’s closed and closes the gate if it’s open (open-close programming option). Activating the input while the gate is moving will reverse the gate. Can be programmed to stop the gate while the gate is moving (open-stop-close programming option). Fire Department Input Fully opens the gate when the input is activated. Overrides the Mid-travel Stop and Auto Close Timer (if either is programmed for the gate). The gate will lockout in the open position without sounding the alarm. Press the STOP button to release the lockout. Open Input Functions the same as the OPEN button. Open Obstruction While the gate is opening, any open obstruction signal will cause the gate to stop, reverse a short distance, and then stop again. The Auto Close Timer will be disabled, and a renewed input will be required to start the gate again. Should the gate be restarted and the obstacle signal occur again prior to reaching a limit, the gate will stop again, lockout, and sound the emergency alarm. Close Obstruction While the gate is closing, any close obstruction signal will cause the gate to stop, reverse, and travel to the full open position. Should a open obstruction input or an open direction inherent entrapment condition occur prior to the gate reaching the open limit, the operator will lockout and sound the continuous tone alarm. Another close request will be required to start the operator again. If after restart, the overload or a close obstacle happens again before the close limit is reached, the operator will lockout and sound the alarm. If the auto close timer is set, when the close obstruction input is cleared, the gate will close when the auto close timer expires. Reverse Input If the reverse input is triggered while the gate is closing, the gate will reverse to the full open position. If the Auto Close Timer is set, when the reverse input is cleared, the gate will close when the Auto Close Timer expires. Open Loop Functions the same as the OPEN button. Reverse Loop Functions the same as the reverse input. Shadow/reset Loop Only used with Swing Gates. Holds the gate fully open or fully closed while triggered. If open, the gate closes immediately when cleared if Anti-tailgate is enabled. Operation Indications During normal operation, the Controller’s displays will indicate current operating conditions and status. Power-up Display When the Controller powers up, dashes will show on the display, then the firmware version number, then the gate type (SL for slide and swing gates). Exiting programming restarts the Controller. The power-up display will show upon the restart. Idle Condition While the Controller is idling, waiting for a command, the display will show circulating dashes. For DC models only - Clockwise : Batteries discharging, Counterclockwise : Batteries charging. Last Gate Position/Condition When the gate moves or stops, the display will show the status for up to one minute. • Stop is displayed as St • Full Close is displayed as FC • Full Open is displayed as FO • Entrapment is displayed as En Pre-start Delay During the pre-start delay, the display will countdown the number of seconds remaining before the operator starts. Reverse Delay If the gate travel direction is reversed from a user activation or reversing device, and ...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - SLD (949.83 kb)
Safety Gate - SLR (949.83 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien