Login:
Stimmen - 5, Durchschnittliche Bewertung: 4.2 ( )

Anleitung Linear, modell SLD

Hersteller: Linear
Dateigröße: 949.83 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


DC AC ACCESSORY POWER PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) DC + RESET RESET BUTTON FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON. COMMON B COMM LINK FOR 3-WIRE NETWORK CONNECTION TO SECOND OPERATOR IN DUAL GATE INSTALLATIONS. A COMMON CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES SINGLE BUTTON INPUT BETWEEN OPEN-CLOSE OR OPEN-STOP-CLOSE DEPENDING ON PROGRAMMING. COMMON SINGLE FIRE BOX INPUT CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPARTMENT ACCESS. FIRE DEPT COMMON CONNECT TO NORMALLY OPEN DEVICES (KEYPAD, CARD READER, KEYSWITCH, OPEN INPUT TELEPHONE ENTRY SYSTEM) TO OPEN THE GATE. A CONSTANT OPEN INPUT WILL OPEN OVERRIDE THE MID-TRAVEL STOP AND HALT THE AUTO CLOSE TIMER UNTIL RELEASED. OPEN CLOSE 3-BUTTON CONNECT TO 3-BUTTON STATION FOR OPEN-CLOSE-STOP CONTROL. A CONSTANT OPEN INPUT COMMON STATION INPUT WILL OVERRIDE THE MID-TRAVEL STOP AND HALT THE AUTO CLOSE TIMER UNTIL RELEASED. STOP CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN COM OBSTRUCTION DURING OPENING. WHILE GATE IS MOVING, ANY OPEN OBSTRUCTION OPEN SIGNAL WILL CAUSE THE GATE TO STOP, REVERSE A SHORT DISTANCE, AND THEN STOP OBSTRUCTION AGAIN. AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED, AND A RENEWED INPUT INPUT WILL BE REQUIRED TO START THE GATE AGAIN. SHOULD THE GATE BE RESTARTED O-OBS AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REACHING A LIMIT, THE GATE WILL STOP AGAIN, LOCKOUT, AND SOUND THE CONTINUOUS TONE ALARM. CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN C-OBS OBSTRUCTION DURING CLOSING. WHILE GATE IS MOVING, ANY CLOSE OBSTRUCTION SIGNAL WILL CAUSE THE GATE TO STOP, THEN REVERSE AND TRAVEL TO THE FULL CLOSE OPEN POSITION. SHOULD A OPEN OBSTRUCTION INPUT OR AN OPEN DIRECTION OBSTRUCTION INHERENT ENTRAPMENT CONDITION OCCUR PRIOR TO THE GATE REACHING THE INPUT OPEN LIMIT, THE OPERATOR WILL LOCKOUT AND SOUND THE CONTINUOUS TONE COM ALARM. IF THE AUTO CLOSE TIMER IS SET, WHEN THE CLOSE OBSTRUCTION INPUT IS CLEARED, THE GATE WILL CLOSE WHEN THE AUTO CLOSE TIMER EXPIRES. COM CONNECT TO NORMALLY OPEN DEVICES TO CAUSE A REVERSAL WHEN THE GATE IS REVERSE TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION. OPEN LOOP REV CONNECT TO OPEN LOOP/FREE EXIT LOOP. THE GATE WILL OPEN OPEN LOOP OPEN LOOP WHEN THE LOOP IS TRIGGERED, AND REMAIN OPEN AS LONG AS THE LOOP IS TRIGGERED. REQUIRES LOOP DETECTOR. REVERSE LOOP CONNECT TO REVERSE LOOP. TRIGGERING THE LOOP WILL CAUSE A REVERSE LOOP REVERSE LOOP REVERSAL WHEN THE GATE IS TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION. REQUIRES LOOP DETECTOR. SHADOW/RESET LOOP CONNECT TO SHADOW/RESET LOOP TO KEEP THE GATE IN ITS FULLY OPEN SHADOW/RESET LOOP POSITION AS LONG AS THE SIGNAL IS PRESENT. USED TO KEEP GATE OPEN SHADOW/RESET LOOP WHILE VEHICLE IS PASSING THROUGH. REQUIRES LOOP DETECTOR. - ALARM FACTORY CONNECTED TO THE ALARM BEEPER. + N.O. FOR CONNECTION TO AUXILIARY DEVICES (MAGNETIC LOCK, SOLENOID LOCK, COM AUX RELAY STROBE LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION. N.C. + 24 VOLT SOLAR PANEL FOR CONNECTION TO 24 VOLT SOLAR PANEL FOR BATTERY CHARGING. - + 24 VOLT BATTERY FACTORY CONNECTED TO BATTERIES IN DC MODEL OPERATORS. - SLR • SLC • SLD Slide Gate Operator Installation Guide - 9 -227968 Revision X19 8-11-2011 SLR • SLC • SLD Slide Gate Operator Installation Guide - 10 - 227968 Revision X19 8-11-2011 Operator Accessory Connections 3-BUTTON STATION KEYSWITCH FIRE ACCESS SWITCH SINGLE-CHANNEL RADIO RECEIVER WIRELESS GATE EDGE SENSOR MGT TRANSMITTER PHOTOEYE FOR REVERSE PHOTOEYE FOR OPEN OBSTRUCTION TELEPHONE ENTRY KEYPAD EXTERNAL POWER SOLENOID LOCK MAGLOCK WARNING STROBE OR AUDIBLE SOUNDER GATE EDGE SENSOR FOR REVERSE CHANNEL #1 OPEN/CLOSE TWO-CHANNEL RADIO RECEIVER PHOTOEYE FOR CLOSE OBSTRUCTION Figure 11. Operator Accessory Connections Basic Controller Programming Programming Overview The Controller can be programmed with various options for the operator. The programming fields are defined as “functions” that have “options”. To make setup easier for the installer, the Controller’s programming is divided into two groups: basic and advanced. The basic programming group contains the functions commonly used in most slide gate installations. The advanced programming group contains functions less commonly used (i.e. dual gate stagger delay, maximum run timer, etc.). Entering Programming Mode Enter programming mode by pressing the UP and DOWN buttons together for one second. While in programming mode the PROGRAM indicator will light. Exiting Programming Mode Exit programming mode at any time by pressing the UP and DOWN buttons together. The Controller will automatically exit programming mode after three minutes of inactivity. Programming Keystrokes (Typical Programming Method) While in programming mode, press the UP or DOWN buttons to scroll through the programming functions. When the desired function is displayed press the ENTER button to display ...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - SLC (949.83 kb)
Safety Gate - SLR (949.83 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien