Hersteller: Linear
Dateigröße: 949.83 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The controller can also be set to prevent the gate from opening if the shadow loop is triggered while the gate is at the close limit position. This prevents a swing gate from opening into a vehicle if it’s parked near the gate on the inside. Low Power Mode This function is only used with DC slide gate Model SLD. The factory default disables the Low Power Mode.When Low Power Mode is enabled, and AC power fails, the controller will assume Low Power Mode after 60 seconds of gate inactivity. Low power mode turns off all accessory power and indicators. Only inputs from the radio receiver, reverse loop, open loop (optional by programming), fire department input, or restoring AC power will wake the Controller from Low Power Mode. Programming Mode can still be accessed while the Controller is awake in Low Power Mode. . NOTE: This function will only be displayed in Model SLD operators. Power Failure Mode This function is only used with DC slide gate Model SLD. The factory default is set for Fail Safe, alternately the Controller can be set for Fail Secure, Open Immediate, or Close Immediate. • Fail Safe: If the AC power fails and the battery voltage drops below approximately 22 Volts, 5 seconds later the operator will cycle open if not already open. When AC power is restored, or the battery gets charged by solar panels, the operator will resume normal operation and auto-close if programmed to do so. • Fail Secure: If the AC power fails and the battery voltage drops below approximately 22 Volts, 5 seconds later the operator will cycle closed if not already closed. When AC power is restored, or the battery gets charged by solar panels, the operator will resume normal operation. . NOTE: Fail Safe and Fail Secure are disabled if Stagger Mode is enabled. • Open Immediate: If the AC power fails, the operator will cycle open if not already open and cease operation. When AC power is restored, the operator will resume normal operation and auto-close if programmed to do so. • Close Immediate: If the AC power fails, the operator will cycle closed if not already closed and cease operation.When AC power is restored, the operator will resume normal operation. . NOTE: This function will only be displayed in Model SLD operators. FUNCTION OPTIONS STANDARD OPERATION "SP" SHADOW LOOP INHIBITS CLOSING ONLY SHADOW LOOP OPEN PREVENTION OPEN INHIBIT ON, SHADOW LOOP INHIBITS OPENING AND CLOSING PRESS UP OR DOWN TO CYCLE THROUGH OPTIONS PRESS ENTER TO SELECT AN OPTION FUNCTION OPTIONS LOW POWER MODE DISABLED "LP" LOW POWER MODE #1 DOWN TO CYCLE PRESS UP OR RADIO WILL WAKE AND ACTIVATE, THROUGH OPTIONS REVERSE LOOP WILL JUST WAKE PRESS ENTER TO LOW POWER MODE #2 -RADIO OR SELECT AN OPTION OPEN LOOP WILL WAKE AND ACTIVATE, REVERSE LOOP WILL JUST WAKE LOW POWER MODE THE FIRE DEPARTMENT INPUT WILL ALWAYS WAKE UP CONTROLLER DC MODELSONLY FUNCTION SET TO FAIL SAFE MODE OPTIONS PRESS UP OR DOWN TO CYCLE THROUGH OPTIONS PRESS ENTER TO SELECT AN OPTION POWER FAILURE MODE "FS" SET TO FAIL SECURE MODE DC MODELS ONLY SET TO OPEN IMMEDIATE MODE SET TO CLOSE IMMEDIATE MODE SLR • SLC • SLD Slide Gate Operator Installation Guide - 15 - 227968 Revision X19 8-11-2011 Advanced Controller Programming (Cont.) Soft Start/Stop Duration This function is only used with DC slide gate Model SLD. This function causes the operator to start and stop the DC motor slowly reducing gate wear and tear (at the full open or closed positions only). The factory default sets the Soft Start/Stop Duration to 3 seconds. The Soft Start/Stop Duration can be set from 1 to 10 seconds. . NOTE: Changing the Soft Start/Stop Duration will reset the open and close current setting value to zero. It will be necessary to reprogram maximum open and close current settings. . NOTE: This function will only be displayed in Model SLD operators set for DC motor operation with soft start motor selection. Reset Cycle Count The Controller counts of the number of times the operator has been cycled full open and close. The cycle count can be displayed. The display will scroll the cycle count number, flashing two digits at a time from left to right. To reset the Cycle Count, press and hold the ENTER button for 2 seconds while the Cycle Count is displayed. If the Maintenance Alert has been triggered, resetting the Cycle Count will also reset the Maintenance Alert indicator. Maintenance Alert Trigger The Controller has a MAINT ALERT indicator that can be programmed to light when the number of activations exceeds a set number of cycles. The factory default sets the Maintenance Alert Trigger to 10,000 cycles. The Maintenance Alert Trigger can be programmed for 5, 10, 15, or 25 thousand cycles. The Maintenance Cycle Count can be reset independently from the operator’s absolute Cycle Count. FUNCTION OPTIONS SOFT START DISABLED "SS" SET SOFT START DURATION TIME FROM 1 TO 10 SECONDS PRESS UP OR DOWN TO CYCLE THROUGH OPTIONS SOFT START/STOP DURATION PRESS ENTER TO SELECT AN OPTION DC MODELS ONLY FUNCTION PRESS ENTER ...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - SLC (949.83 kb)
Safety Gate - SLD (949.83 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien