An alternate method would be to use wall anchors. Whichever method you use, make sure the air cleaner is mounted in a sturdy fashion to prevent it from pulling loose. © 1997 Grizzly Industrial, Inc. G4702 & G4705 INSTALLATION INSTRUCTIONS The G4702 & G4705 Air Cleaners can be mounted on the floor, wall or a ceiling; whichever place is convenient. If mounting on a wall or ceiling, we recommend attaching the air cleaner to the wall or ceiling studs using sheetrock screws. This will require at

heruntergeladen wurde: 4   Dateigröße: 36 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

This will require at least four holes be drilled corresponding to the stud spacing. An alternate method would be to use wall anchors. Whichever method you use, make sure the air cleaner is mounted in a sturdy fashion to prevent it from pulling loose. © 1997 Grizzly Industrial, Inc.

heruntergeladen wurde: 2   Dateigröße: 163 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

1706 Canterbury Rd Greenville, NC 27858 Ph. 252.355.6789 Oysterdoctor@aol.com Efficiency Of Bacterial Disinfection By A Duct Mounted UV-AireO Air Purifier For: Table of Contents Table of Contents Background ..........................................................................................................................3 Organism.........................................................................................................................3 Testing Structure.....................

heruntergeladen wurde: 0   Dateigröße: 177 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

(See Figure 1) 2. Bend tabs outward as shown in Figure 2. 3. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See Figure 3) 4. Remove the cut piece of duct. (See Figure 4) 5. Bend both tabs down and through duct at first bend point. (See Figures 5 & 6) 6. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 7 & 8) 7 Using a screwdriver or pointed object, locate mountin

heruntergeladen wurde: 0   Dateigröße: 177 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

(See Figure 1) 2. Bend tabs outward as shown in Figure 2. 3. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See Figure 3) 4. Remove the cut piece of duct. (See Figure 4) 5. Bend both tabs down and through duct at first bend point. (See Figures 5 & 6) 6. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 7 & 8) 7 Using a screwdriver or pointed object, locate mountin

heruntergeladen wurde: 6   Dateigröße: 244 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

7. Drill the marked mounting holes with a 1/8 inch diameter drill bit. Remove the marked filter opening with metal cutting shears or equivalent. 8. Attach filter cabinet to the appliance or duct work using #8 X 1/2 inch long sheet metal screws or pop rivets. Seal the housing connections with aluminum duct tape or equivalent. 9. Remove media filter from the plastic bag and discard the plastic bag. TIP: Write the installation date on filter next to directional arrow for future filter replacement r

heruntergeladen wurde: 3   Dateigröße: 244 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

*The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction. WARNING: Read the installation instructions carefully and completely before proceeding with the installation. GENE

heruntergeladen wurde: 0   Dateigröße: 370 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 2 7. Insert the ceramic tip of the lamp into the UV port and twist the lamp connector clockwise to lock in place. (See Figure 3) Figure 3 8. With unit still UNPLUGGED, insert the lamp power connector into the recessed receptacle on the unit. (See Figure 4) Figure 4 9. Close the access do

heruntergeladen wurde: 0   Dateigröße: 638 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

Please retain these instructions after installation. Installed By: Phone: Installation Date: page 2 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. INSTALLATION Determine a suitable l 1. ocation on either the supply or return for the unit as shown in Figure 1. The unit must b

heruntergeladen wurde: 1   Dateigröße: 649 kb   Hersteller: Field Controls  
Kategorie: Luftreiniger
@name

GENERAL INFORMATION There are different size units available, depending on the square footage of your home. See chart below for determining your home’s needs. Model Minimum Duct Width Volts Amps Hz Watts Max Air Temp .F Lamp Intensity at 1 meter Recommended Max Sq. Feet UV-18X 14" 120 1.0 60 60 190O 2 @ 73 .W/cm2 4000 WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have units unplugged. Electrical shock can cause pe





Kategorien