Anleitung Zusammenfassung


They are factory-assembled flanged units suitable for gel sealed or gasket sealed HEPA filters. Both the prefilters and the primary HEPA/ULPA filters are serviceable through the same gasketed side access door. Versatility C-3 and C-4 housings may be used with Alpha 95 filters (95% DOP efficiency) and with Alpha Cell and Alpha 2000 filters (99.97% and 99.99% DOP efficiency). Standard housings accept nominal 12 inch deep filters and 16” and 18” carbon adsorbers in a variety of face sizes. They can be arranged from one filter high and one filter wide to four filters high and eight filters wide. If large housings are not practical to rig into place, smaller units may be stacked in the field. Options • Choce of frame construction materials • Insulation • Lifting lugs • Transitions • Static pressure ports • DOP test ports • High temperature modifications • Weathercap • Magnahelic gauges (mounted) • PrefilterTrack Construction Housings are 24 inches deep in the direction of air flow, (26 inches deep if it has a 4” prefilter section.) and are constructed in your choce of frame materials. Flanges are furnished for duct connections on the air entering and air leaving sides. All joints are intermittently welded and finished to remove all burrs and sharp edges. The joints are then sealed with silicone enabling the housing to withstand an internal pressure of +/- 3.0 in. w.g. The filter locking mechanism for the fluid gel seal- model housing is a 300 Series stainless steel hand- operated arm that moves the filter s gel-filled channel on to the internal housing knife edge sealing flange. The same mechanism also pulls the filter away from the sealing flange when changing filters. The filter locking mechanism for gasket seal-model housing is a 300 Series stainless steel and brass device. The mechanism presses the gasketed filter against the housing s sealing surface by means of a mechanical bolt and thrust assembly that is manually operated using a standard 3/4 inch socket or wrench. Standard 2 inch or 4 inch prefilter tracks will accommodate pleated panel filters with efficiency ranges up to 50% per the ASHRAE Standard 52.2 dust spot test methods. Access doors have 0.5 in. thick closed cell neoprene gaskets around the inside perimeter. Double pin door hinges which pivot, allow the door to make level contact with the gasket when closed. Stainless steel wing nuts secure the doors. Cfm Capacities and Dimensions Using Standard Alpha 95 and Alpha Cell and High Capacity Alpha 2000 HEPA Filters Height Code 1H Face Velocity (fpm) 500 Width Code 1W 2W 3W 4W 5W 6W 7W 8W CFM Capacity 1000 4000 6000 8000 10000 12000 14000 16000 275 1100 2200 3300 4400 5500 6600 7700 8800 375 1500 3000 4500 6000 7500 9000 10500 12000 500 2000 4000 6000 8000 10000 12000 14000 16000 2H 500 4000 8000 12000 16000 20000 24000 28000 32000 275 2000 4000 6000 8000 10000 12000 14000 1600 375 3000 6000 9000 12000 15000 18000 21000 24000 500 4000 8000 12000 16000 20000 24000 28000 32000 3H 500 6000 12000 18000 24000 30000 36000 42000 48000 275 3000 6000 9000 12000 15000 18000 21000 24000 375 4500 9000 13500 18000 22500 27000 31500 36000 500 6000 12000 18000 24000 30000 36000 42000 48000 4H 500 8000 16000 24000 32000 40000 48000 56000 64000 275 4000 8000 12000 16000 20000 24000 28000 32000 375 6000 12000 18000 24000 30000 36000 42000 48000 500 8000 16000 24000 32000 40000 48000 56000 64000 1. Height and Width code: the first numeral represents the number of 24 in. x 24 in. filters high and wide. See also Model Number Development on page 3. 2. Standard housing depth is 23-1/4 inches with or without an optional prefilter track. 3. Housings greater than four wide must have filter removal from both sides. 4. Capacities shown are based on nominal 12 inch deep filters. C-3 C-4 A spring-loaded filter clamping mechanism is used to maintain seal- ing pressure for gasketed filters. The gasket seal is suitable for many applications. Gasket Seal Gasket Gel Seal Housing Knife Edge Sealing Flange A flange in the housing mates into a gel-filled channel on the filter. The gel seal guarantees filter-to-frame sealing and is recommended for critical applications. Flanders Filters - Foremost in Air Filtration Toll Free: 1-800-637-2803 Model Number Development C3G -1H1W -GGF -GLV -D1 Housing Material: Filter type: C3G - Gasket Seal GLV: Galvanized steel C4F -Fluid Seal 304: Type 304 S/S Housing Size: 304L: Type 304 L S/S Filters High x Wide 316: Type 316 S/S (See Chart) 316L: Type 316L S/S ALZ - 14 gauge aluminizedFilter Size: CCF - 12”x12”x11-1/2” HEPA Filter 2CCF -12”x12”x11-1/2” HEPA filter with a 2” prefil...

Dieses Handbuch ist für folgende Modelle:
Luftreiniger - Crank Lock HEPA Filter Housing C-4 (248.75 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien