Do not reduce the recommended tubing size. CONDENSATE REMOVAL THIS APPLIANCE EMPLOYS A DRAW-THROUGH COIL, THEREFORE A TRAP MUST BE INSTALLED IN THE DRAIN LINE(S) TO ALLOW FOR PROPER CONDENSATE DISPOSAL. The condensate trap must not be the "running" type, or "R" type. A "P " trap is required. The total workable height of this trap, in inches, must exceed the total negative pressure, in inches of water, as measured in the return duct. UNIT DRAIN CONNECTION FLEXIBLE TUBING-HOSE OR PIPE A POSITIVE 2" MINIMUM 3" MINIMUM LIQUID SEAL IS REQUIRED The condensate drain line must be at least 3/4 NPT, for each unit. Precautions must be used not to over tighten the adapter at the drain pan connection, this precaution will prevent damage to the plastic drain pan. A joint compound should be used to prevent leakage and act as a lubricant. When using copper tubing as a condensate line adequate caution muat be taken to prevent damage to the plastic drain pan during the soldering process. All condensate drain lines and drain traps should be adequately insulated. The unit and the auxiliary drain pan must be adequately elevated to insure proper drainage. Use of a condensate removal pump is permitted when necessary.This condensate pump should have provisions for shutting off the control voltage should a blocked drain occur. A trap must be installed between the unit and the condensate pump. Important: The evaporator coil is coated with oils that will dissolve Styrofoam and certain types of plastics. Therefore a removal pump or float switch must not contain any of these materials. NOTE: AFTER INSTALLATION AND POSITIONING THE UNIT , THE DRAIN PAN BEING USED SHOULD BE TESTED BY FILLING IT WITH WATER TO ENSURE PROPER DRAINAGE AND CHECK FOR LEAKS. 8 ELECTRICAL CONNECTIONS The required electrical power supply information is located on the series and rating plate on the exterior of the unit. Wiring selection must be in accordance with local codes, or in absence of local code, the National Electrical Code. A disconnect means should be installed within sight of the unit, when required by code. Copper wire is recommended for all electrical connections. When an optional heat kit is installed refer to the electrical requirements in that kit. The wiring diagram included in the heat kit must be placed over the wiring diagram on the air handler. All pertinent information, such as the rating plate, included in the optional heat kit must be applied to the Air Handler as indicated. The use of copper connections are recommended inside the control box (see UL 1995, section 37.9). Model No. Min. Ampacity208/230 Max. Over-current 208/230 Blower Motor FLA Blower Motor H.P. HB4200VA1M25 --------15/15 2.2 1/2 HB4800VA1M25 --------15/15 2.2 1/2 HB6000VA1M25 --------15/15 4.0 3/4 Model No. Min. runningAmpacity208/230 Max. Over-current 208/230 Blower Motor FLA Blower Motor H.P. HB3600VC1M25 --------15/15 2.3 1/3 HB6000VC1M25 --------15/15 4.0 3/4 WARNING A MEANS OF STRAIN RELIEF MUST BE INSTALLED TO THIS APPLIANCE AT THE ELECTRICAL SERVICE ENTRANCE. When an optional electric heat kit is installed refer to the electrical requirements for that kit. The ampacity and overcurrent protection shown above is only for "HB" air handlers installed without a heat kit. 9 THERMOSTAT WIRING corresponding terminal according to above control specification. For Thermostat only control Air Conditioning open/stop, hot control Environment temperature, can adopt different power switch show diagram 2. This mode is control the indoor unit & heat pump outdoor unit at the same time no air supply mode. If need select the air supply mode, switch can adopt multi-connect switch or select switch. The detailed infor see the following diagram 3. Above diagram: Outdoor Unit Connection Left: Indoor and Outdoor unit power supply Respectively Right: Indoor unit power supply. For Thermostat Control Environment-temperature and Air Conditioning open/stop, the wiring diagram as shown diagram 1. Thermostat can be mechanical type or programmable type. Note: Thermostat C : COM. TERMOSTAT R : AC24V Y : COMPRESSOR G : FAN O : 4 -WAY VALUE TO INDOOR FAN RELAY For detailed Thermostat, please connect G Y R CO ORYL RD BL CONTROL BL O Y R 24V COM TO OUTDOOR UNIT R,C,Y,O TRANSFORMER C Diagram 1 RUN SWITCH MODE SWITCH RD CYO R Open for heating Close for cooling TO INDOOR FAN RELAY CONTROL BL RD BL 24V COM TO OUTDOOR UNIT R,C,Y,O Diagram 2 SELECT SWITCH 1 2 3 4 5 6 OFF FAN ONLY E. HEAT HEAT PUMP COOLING TO FAN RELAY CONTROL BL YO TO OUTDOOR UNIT R,C,Y,O COM TRANSFORMER 24V C R Diagram 3 TRANSFORMER YL RD BL 10 For Thermostat Control Environment-temperature and Air Conditioning open/stop, the wiring diagram as shown diagram 4. Thermostat can be mechanical type or programmable type. Note: Thermostat C: COM. R : AC24V Y : COMPRESSOR G : FAN For detailed Thermostat, please connect corresponding terminal according to above control specification. For Thermostat only control Air Conditioning open/stop, hot control En...

Dieses Handbuch ist für folgende Modelle:
Luftreiniger - HB4200VA1M25, HB4800VA1M25, HB6000VA1M25, HB6000VC1M25 (254.88 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien