Anleitung Honeywell, modell S9360A

Hersteller: Honeywell
Dateigröße: 1.22 mb
Dateiname: ad76b75a-c0f3-4a06-b130-ecea5f97dab3.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• S9360A—Spark Ignition, Intermittent Pilot, Remote Display. • S9361A—Spark Ignition, Intermittent Pilot, “On board” Display. • S9370A—Hot Surface Ignition, Remote Display. • S9371A—Hot Surface Ignition, “On board” Display. • Enabled with EnviraCOM™ communication capability to support remote monitoring and diagnostics. • Limit-rated Temperature Sensing Probe. • One or Two Sensor Models. SPECIFICATIONS IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, an individual unit may not match the listed specifications exactly. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Model Numbers Dimensions: See Fig. 1. S—Switching Control 9 3—Integrated Hydronic Control Platform 6—Spark Ignition 7—Hot Surface Ignition 0—Remote Display Required 1—Integrated On-Board Display A—Boiler Control B—Water Heater Control C—Pool Heater Control 1—No Circulator 2—On/Off Circulator S 9 3 6 0 A 1 000 69-2076-01 S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS 5/8 (16) M24217 2 x 84.5 2 x 15 2 x 61 220.5 111 2 x 15 I S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS 5/8 (16) M24217 2 x 84.5 2 x 15 2 x 61 220.5 111 2 x 15 I Fig. 1. S936X Integrated Boiler Controller, dimensions in in. (mm). Electrical Ratings: Line Voltage: 120 Vac, 60 Hz (220 Vac, 50 Hz on specific model numbers). Transformer: Nominal 24 Vac (maximum 30 Vac, minimum 18 Vac). 5.0 VA plus external loads (gas valve, vent damper, etc.) On/Off Circulator: Full Load: 7.4A at 120 Vac (0.75 to 0.8 power factor [PF]). (220 Vac TBD.) Locked Rotor: 44.4A at 120 Vac (0.4 to 0.5 PF). (220 Vac TBD.) Inducer (Optional): Full Load: 6A at 120 Vac (0.75 to 0.8 PF). (220 Vac TBD.) Locked Rotor: 17.48A at 120 Vac (0.4 to 0.5 PF). (220 Vac TBD.) Vent Damper (Optional): Full Load: 0.5A at 24 Vac. In Rush: 1A at 24 Vac. Main Valve: Full Load: 2A at 24 Vac (0.5 to 0.6 PF). In Rush: 6A at 24 Vac (0.5 to 0.6 PF) Pilot Valve (Optional): Full Load: 2A at 24 Vac (0.5 to 0.6 PF) In Rush: 6A at 24 Vac (0.5 to 0.6 PF). Hot Surface Igniter (HSI) (Optional): Full Load: 4.5A at 120 Vac. Warm-up Time: 18 seconds for first trial for ignition; this varies by model, as does the time for the second trial for ignition (recommended for Norton igniter model 201 or 270 or equivalent) Ambient Ratings: Humidity: 0 to 95 percent relative humidity, noncondensing. Operating Ambient Temperature: -30°F to +150°F. Shipping Ambient Temperature: -40°F to +175°F. Flame Monitoring (May vary by model): Flame Establishing Period (FEP): Maximum 2 seconds. Flame Failure Response Time (FFRT): Maximum: 2 seconds @ 1 .A. Flame Stabilization Time: 4 seconds. Time from ignit ing the main burner and detecting loss of flame (the flame current is allowed to be under the flame lost threshold for this time while waiting for burner to stabilize). Flame Lost Threshold: 0.23 ...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - S9360A (1.22 mb)
Warmwasserbereiter - S9361A (1.22 mb)
Warmwasserbereiter - S9370A (1.22 mb)
Warmwasserbereiter - S9371A (1.22 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien