Anleitung A.O. Smith, modell S9360A

Hersteller: A.O. Smith
Dateigröße: 1.22 mb
Dateiname: ad76b75a-c0f3-4a06-b130-ecea5f97dab3.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Operating Ambient Temperature: -30°F to +150°F. Shipping Ambient Temperature: -40°F to +175°F. Flame Monitoring (May vary by model): Flame Establishing Period (FEP): Maximum 2 seconds. Flame Failure Response Time (FFRT): Maximum: 2 seconds @ 1 .A. Flame Stabilization Time: 4 seconds. Time from ignit ing the main burner and detecting loss of flame (the flame current is allowed to be under the flame lost threshold for this time while waiting for burner to stabilize). Flame Lost Threshold: 0.23 .A. Ignition Cables: Use cable types recommended in Table 1. 69-2076—01 2 S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS Cable Type VoltageRating (rms) Temperature Rating °C °F UL Style 3217 10,000 150 302 UL Style 3257 10,000 250 484 Transformer Requirement: Add current ratings of module, pilot valve, main valve, vent damper and any other components of the control system to determine transformer size requirement. Approvals: Varies with control model. ANSI Z21.20 Automatic Gas Ignition Systems and Components. ANSI Z21.23 Gas Appliance Thermostats. EN298: Automatic Gas Burner Control Systems ANSI Z21.87: Automatic Gas Shutoff Devices for Hot Water Supply Systems. UL353 Limit Controls. PLANNING THE INSTALLATION Automatic Ignition Control domestic and commercial boiler systems are used on a wide variety of equipment. Some of these applications may make heavy demands on the controls, either because of frequent cycling, or because of moisture, corrosive chemicals, dust or excessive heat in the environment. In these situations, special steps may be required to prevent nuisance shutdowns and premature control failures. These applications require Honeywell Engineering review; contact your Honeywell Sales Representative for assistance. Frequent Cycling These controls are designed for use on domestic and commercial boiler systems that typically cycle less than 10,000 cycles per year. In an application with significantly greater cycling rates, we recommend monthly checkout because the controls may wear out more quickly. Water or Steam Cleaning Once a module or gas control has been wet, it may operate unreliably and must be replaced. If the appliance is likely to be cleaned with water or steam, the controls and associated wiring should be covered so that water or steam cannot reach them. The controls should be high enough above the bottom of the cabinet so they will not be subjected to flooding or splashing during normal cleaning procedures. If necessary, shield the controls to protect them from splashing water. A NEMA 4 enclosure is recommended. High Humidity or Dripping Water Over time, dripping water or high ambient humidity can create unwanted electrical paths on the module circuit board, causing the module to fail. Never install an appliance where water can drip on the controls. In addition, high ambient humidity can cause the control to corrode and finally fail. Where the appliance may be in...

Dieses Handbuch ist für folgende Modelle:
Warmwasserbereiter - S9360A (1.22 mb)
Warmwasserbereiter - S9361A (1.22 mb)
Warmwasserbereiter - S9370A (1.22 mb)
Warmwasserbereiter - S9371A (1.22 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien