|
Anleitung Zusammenfassung
4. This loop MUST be connected to the taps. Remove the blanking cap and set aside. 5. Connect the loop to the taps with the wing nuts. These should be hand tightened. 6. Carefully open the handles on both taps and check the boiler pressure gauge. Once the needle on the gauge is above the 0.5 mark both taps can be closed. 7. Undo the two wing nuts, remove the loop and refit the blanking cap. Put the loop in a safe place for future use. © Baxi Heating UK Ltd 2007 4.0 Clearances 5mm Min 450mm 5mm Min 200mm Min (300mm Min if using 80/125mm flueing system) 4.1 For your Safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 2. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations. GB - Heating Industry definition meaning England, Scotland, Wales, Northern Ireland, Isle of Man and the Channel Isles 780mm 200mm Min In Operation 450mm Min For Servicing Purposes 5mm Min Fig. 4 3. Your boiler must not be operated without the casing correctly fitted. 4. Do not interfere with any sealed components on this boiler. 5. Take note of any warning labels on your boiler. 6. Your boiler should have the following minimum clearances for Safety and Maintenance (Fig. 34):Top Bottom Left side Right Side Front - 200mm - 200mm - 5mm - 5mm - 5mm (In Operation) - 450mm (For Servicing) 7. If your boiler is installed in a compartment, do not use it for storage purposes. Do not obstruct any purpose provided ventilation openings. 8. Flammable materials must not be stored in close proximity to your boiler. 9. Avoid skin contact when your boiler is in operation, as some surfaces may get hot e.g. pipework. 10. Ensure that the flue terminal, outside the house, does not become damaged or obstructed, particularly by foliage. 11. It is important that the condensate drain system is not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. © Baxi Heating UK Ltd 2007 5.0 Care of the Boiler 5.1 Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 5.2 Protection & Precaution 1. The boiler incorporates an integral frost protection feature that will operate in both modes. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised. 2. If a system frost thermostat has been fitted (your installer will be able to advise you), then to operate correctly and protect your system, the gas and electricity must be left on and the appliance set in the central heating mode. 3. The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated. To prevent seizure, the pump will operate for approximately 1 minute if it has not run in the last 24 hours. 5.3 Fault Indication 1. If a fault occurs on the boiler an error code may be shown Reset on the facia display (Fig. 5). bar01234 Display Then Fig. 5 Table of Error Codes E20 Central Heating NTC Fault E28 Flue NTC Fault E50 Hot Water NTC Fault E110 Safety Thermostat Operated E119 Water Pressure Switch Not Operated E125 Circulation Fault (Primary Circuit) E130 Flue NTC Operated E133 Interruption Of Gas Supply or Flame Failure E160 Fan or Fan Wiring Fault 2. The codes are either two or three digit, preceded by the letter 'E'. For example, code E133 will be displayed by 'E1' alternating with '33'. E50 is shown as 'E' then '50'. 3. E20, E28, E50, E125 & E160 indicate faulty components. You should make a note of the displayed error code and contact your installer or service engineer. 4. If E110 or E130 is displayed overheat of the primary water or flue system has occurred. Turn the selector switch to the reset position and hold for at least 5 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer. 5. E119 is displayed when the primary water pressure is less than 0.5 bar. After repressurising the system the boiler should operate. Your installer will be able to advise you about the method of repressurising. See page 6 for further details. 6. E133 indicates that the gas supply has been interrupted, ignition has failed or the flame has not been detected. Ensure that the gas supply has not been turned off, and turn the selector switch to the reset position and hold for at least 5 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer. © Baxi Heating UK Ltd 2007 6.0 Legislation Registered Gas Installer CARD SERIAL NO. 999999999 NAME: A.N.Installer COMPANY: Newtown Heating EXPIRES: 31 DECEMBER 2010 PHOTOGRAPH To confirm validit...
Dieses Handbuch ist für folgende Modelle:Warmwasserbereiter - Performa 28 (970.32 kb)
Warmwasserbereiter - 33 HE (970.32 kb)