Anleitung Chamberlain, modell SH-5412

Hersteller: Chamberlain
Dateigröße: 262.07 kb
Dateiname: 598-1158-01.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Model SH-5412 Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. • LED indicates motion was sensed (day or night). This package includes: Rubber Plug Lamp Holders 2 Shells Cover Plate Gasket 6 Screws (3 sizes included) Mounting Strap Mounting Bolt 2 Wire Plastic Connectors Hanger Requirements • The Light Control requires 120-volts AC. • If you want to use Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualified electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. Sensor Light Control OPERATION Mode: On-Time: Works: Day Night Test 5 Sec x x Auto 1, 5, 10 min. x Manual Until Dawn* x * resets to Auto Mode at dawn. Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. TEST 10 5 1 TESTON-TIMEPut the ON-TIME switch on the bottom of the sensor in the TEST position. AUTO ON-TIME10 5 1TESTPut the ON-TIME switch in the 1, 5, or 10 minute position. MANUAL MODE ... back on. 1 Second OFF then... Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second thenbackontotogglebetweenAUTO and MANUAL MODE. ManualmodeworksonlywiththeON-TIMEswitchinthe1,5,or10position. Mode Switching Summary Move ON-TIME Switch to 1, 5, or 10 minutes AUTO Flip light switch off for one second then back on* MANUAL MODE * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. © 2006 DESA Specialty Products™ 598-1158-01 . Twistthejunction box wires and fixture wires together INSTALLATION as shown. Secure with wire connectors. For easy installation, select an existing light with a wall switch for replacement. Wall Mount Eave Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. For eave mount only: . Swingthesensorheadtowardstheclampscrewjoint. If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint.Tighten the clamp screw when done. . Then rotate the sensor head clockwise 180° so the controls face down. ControlsControlsControlsClamp Screw WIRE THE LIGHT CONTROL . Turn power off at the fuse or circuit breaker. . Remove the existing light fixture. . Install the mountingstrap asshown using two screws that fit your junction box. . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. . Route the Light Control’s wires through the large gasket holes. White to WhiteBlack to BlackJunction box ground wire to green ground screw on fixture. GasketMounting StrapMounting BoltRubber Plug MOUNT THE LIGHT CONTROL . Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt. . Align the three slots in the decorative shell with the lamp holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell. Shell Slot . Push the Rubber Plug firmly into place. . If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant. To avoid water damage and electrical shock, keep lamp holders 30° below horizontal. Keep lamps at least 1" (2.5 cm) from the sensor.Do not allow the lamps to block the lens. Lock NutLens . Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten. 2 598-1158-01 (2.4 m)(2.4 m) TEST AND ADJUSTMENT . Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes. . Turn the RANGE control to the mid position and the ON-TIME control to the TEST position. RANGE10 5 1 TESTON-TIMEMAXMIN RANGE ON-TIME 10 5 1 TEST MINUTES MIN MAX Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. 8 ft. 180° 70 ft. (21 m) Maximum Range Maximum Coverage Angle The detector is most sensitive to motion across its field of view. Motion Motion Sensor Least Sensitive Most Sensitive WARNING: Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m). SPECIFICATIONS Range . . . . . . . . . . . . Up to 70 ft.(21 m) [varies with surrounding temperature]. Sensing Angle. . . . . . Up to 180° Electric...

Dieses Handbuch ist für folgende Modelle:
Überwachungstechnik - SH-5412 (262.07 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien