Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Desa, modell DUALBRITE SH-5597

Hersteller: Desa
Dateigröße: 267.23 kb
Dateiname: 598-1162-01.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Coverage Do not overtighten the screw. . Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes). . Set the DUALBRITE® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn). NOTE: DUALZONE™ is a new zone of detection which wasaddedasanoptiontoselectHeath®/Zenithmotion sensing products. This feature adds a zone of detection under the motion sensor. DUALZONE™ requires no additional adjustment and operates in conjuction with the forward-looking sensor. 15 ft. (4.6 m) 70 ft.100 ft. 240° DUALZONE™ DUALZONE™ (21 m) (30.5 m) Boosted Maximum Maximum Range Coverage Angle The detector is less sensitive to motion directly towards it. Motion DUALZONE™ Sensor Least Sensitive Most Sensitive MotionDUALZONE™ SPECIFICATIONS Horizontal Range. . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature] Vertical Range. . . . . . Up to 15 ft. (4.6 m) Sensing Angle . . . . . . Up to 240° horizontal. Up to 80° Vertical Electrical Load. . . . . . Up to 200 Watt Maximum Incandescent [Up to 100 Watt Maximum each lamp holder.] Power Requirements . 120 VAC, 60 Hz Operating Modes . . . . TEST, AUTO, and MANUAL MODE Time Delay . . . . . . . . 1, 5, 20 minutes DUALBRITE® Timer . . . . 3, 6 hours, Dusk-to-Dawn Replacement lamp. . . T4 100W, G8 halogen bi-pin 120 VAC DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold. 598-1162-01 3 TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE Lights will 1. Light switch is turned off. not come 2. Light is loose or burned out. on. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turnoff is in effect (recheck after dark). 5. Incorrect circuit wiring, if this is a new installation. 6. Re-aim the sensor to cover desired area. Lights come 1. Light Control may be installed in a on in day-relatively dark location. light. 2. Light Control is in Test. (Set control switch to an ON-TIME position). Lights come 1. Light Control may be sensing small on for no animals or automobile traffic (re-aim apparent sensor). reason. 2. Range is set too high. (Reduce Range setting). 3. DUALBRITE® Timer is on. Lights turn off too late in Duskto- Dawn setting. 1. Sensor is in a relatively dark location. (Relocate sensor, or use 3 hr or 6 hr setting). SYMPTOM POSSIBLE CAUSE Lights stay 1. A lamp is positioned too close to the on continusensor or pointed at nearby objects ously. that cause heat to trigger the sensor. (Reposition the lamp away from the sensor or nearby objects). 2. Light Control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface. (Reposition sensor. Reduce Range). 3. Light Control is in Manual Mode. (Switch to Auto). Lights flash 1. Heat or light from the lamps may be on and off. turning the Light Control on and off. (Reposition the lamps away from the sensor). 2. Heat being reflected from other objects may be affecting the sensor. (Reposition sensor). 3. Light Control is in the Test mode and warming up.(Flashing is normal under these conditions. Turn Boost off). Lights flash 1. Sensor is detecting its own lights. once, then (Reposition lamps to keep area below stay off in the sensor relatively dark). Manual Mode. TECHNICAL SERVICE Please call 1-800-858-8501 for assistance before returning product to store. If you experience a problem, follow this guide. You may also want to visit our Web site at: If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F).You may also write* to: DESA Specialty Products™ P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service Specialty Products * If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase. No Service Parts Available for this Product TEN YEAR LIMITED WARRANTYThisisa“LimitedWarranty”whichgivesyouspecificlegalrights.Youmayalsohaveotherrightswhichvaryfromstatetostateorprovincetoprovince. For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be cor- rected at no charge to you. Not Covered -Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expend- able items are not covered by this warranty.Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety.This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THISWARRANTYISEXPRESSLYIN...

Dieses Handbuch ist für folgende Modelle:
Überwachungstechnik - DUALBRITE SH-5597 (267.23 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien