Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung EverFocus, modell EDSR-600

Hersteller: EverFocus
Dateigröße: 1.03 mb
Dateiname: 31e09e2b-c23f-496f-b124-4d9aa12d8b51.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


SPEED : To set the alarm and motion recording speed. Maximum 60 (NTSC) / 50 (PAL). QUALITY: Video recording quality setup, this item lets you set the quality of the video picture by selecting a compression rate. NOTE: The recording rates are for the total system: The single camera record rate is: Camera record rate = System record rate / Number of connected cameras Example: Record Rate 60 IPS, 6 connected cameras: 10 IPS / camera (3) PRE-ALARM RECORD: (with Alarm In and Motion) Pre – Alarm duration is depending on record quality (about 8-15 seconds). OP (Operation): Select ON or OFF to activate pre-alarm recording or not . Turn the JOG dial clockwise or counter-clockwise to select the options. Press ENTER key to confirm the option and move to next column. ENTER Press CALL key to confirm the option and move to previous column. CALL Press MENU key to return to Main Menu, press again to leave Set up Menu. MENU 19 MENU 6.9 NETWORK SETTING MENU NETWORK SETTING MENU IP ADDRESS : 192.168.010.005 NET MASK ADDRESS : 255.255.255.000 GATEWAY ADDRESS : 192.168.010.001 MAC ADDRESS : 00:5A:56:A3:87:1A USER-NAME PASSWORD LEVEL GUEST--GUEST-- GUEST-- GENERALGENERALGENERALADMIN-- ADMIN-- ADMIN-- In the NETWORK SETTING MENU, we define (1) IP ADDRESS : Assign an fixed IP address for this unit, for example:192.168.010.005 (2) NET MASK ADDRESS: Assign a subnet mask of the network for this unit, for example:255.255.255.000 (3) GATEWAY ADDRESS: Assign a default gateway for this unit, for example:192.168.010.001 (4) MAC ADDRESS: Hardware address of the network interface. Do not modify without instruction of network administrator. Note: After changing network settings, screen will comes up as following: Network setting………………………………. Please reboot to effect network setting After restart of EDSR the new network settings are activated. (5) USER-NAME PASSWORD LEVEL The Login name and password are used to establish a network connection to the unit. The PASSWORD setup allows the administrator to set the new Login name and password with access level “ADMIN”,”GENERAL”or “GUEST”. The system allows up to four users connected at same time with different access levels. “ADMIN ”: can view live/playback video, covert cameras and control all operation/setup. “GENERAL”: can view live and playback video. “GUEST”:can only view live display. Turn the JOG dial clockwise or counter-clockwise to select the options. Press ENTER key to confirm the option and move to next column. ENTER Press CALL key to confirm the option and move to previous column. CALL Press MENU key to return to Main Menu, press again to leave Set up Menu. MENU 20 MENU 6.10 CONTROL SETTING MENU CONTROL SETTING MENU RS232 BAUD RATE : 9600 BPS RS232 STOP BIT : 1 RS232 PARITY : NONE RS232 DATA BIT : 8 RS485 BAUD RATE : 9600 BPS RS485 STOP BIT : 1 RS485 PARITY : NONE RS485 DATA BIT : 8 RS232/RS485 ID : 001 In the CONTROL SETTING MENU, we define (1) RS232 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS232 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 3840 baud. The default setting from the factory is 9600 baud. (2) RS232 STOP BIT: Select stop bit: 1 or 2 (3) RS232 PARITY: Select parity mode: NONE/ODD/EVEN (4) RS232 DATA BIT: Select data bit : 8 or 7 (5) RS485 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS485 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 3840 baud. (6) RS485 STOP BIT: Select stop bit: 1 or 2 (7) RS485 PARITY: Select parity lever: NONE/ODE/EVEN (8) RS485 DATA BIT: Select data bit : 8 or 7 (9) RS232/RS485 ID: RS232/RS485 address.The address range for the DVR: 001~200. NOTE: Settings for remote keyboards KS-KBK and KS-KBJ: RS-485 Baud rate: 9600, 1 Stop bit, Parity NONE, ID (device number) range: 1~32 Press ENTER key to confirm the option and move to next column. ENTER Turn the JOG dial clockwise or counter-clockwise to select the options. Press CALL key to confirm the option and move to previous column. CALL Press MENU key to return to Main Menu, press again to leave Set up Menu. MENU 21 MENU 6.11 BUZZER SETTING MENU BUZZER SETTING MENU BUZZER : ENABLE RECORD-IN : ON ALARM-IN : ON MOTION-IN : ON DISK FULL : ON VIDEO LOSS : ON TIMER : ON In BUZZER SETTING MENU, we define the buzzer ON/OFF for following event: RECORD-IN, ALARM-IN, MOTION-IN, DISK FULL, VIDEO LOSS AND TIMER Press ENTER key to confirm the option and move to next column. ENTER Turn the JOG dial clockwise or counter-clockwise to select the options. Press CALL key to confirm the option and move to previous column. CALL Press MENU key to return to Main Menu, press again to leave Set up Menu. MENU 22 MENU 6.12 ARCHIVE SETTING MENU ARCHIVE SETTING MENU PICTURE SIZE : 720 X 480 TIME STAMP : ON TIME STAMP POS : TOP WATER MARK : ON WATER MARK POS : TOP In the ARCHIVE SETTING MENU, we define for picture and movie export to CF-card: (1) PICTU...

Dieses Handbuch ist für folgende Modelle:
Überwachungstechnik - EDSR-400 (1.03 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien