Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Health O Meter, modell PROFESSIONAL 599KL

Hersteller: Health O Meter
Dateigröße: 659.93 kb
Dateiname: 597-599-752-manual.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


4. To use the BMI feature, place the patient on the scale platform; press the BMI button. The scale will prompt you to enter the patient’s height. Use the arrow (scroll) keys to find the correct height (the default height is 5 ft. 6.0 in.). Press ENTER. Display will read the patient’s BMI. Weight may remain displayed on the scale by pressing the HOLD/RELEASE button. To release, press the HOLD/RELEASE button again. NOTE: The scale will always default to the settings and units last used. * To change the scale default units to kilograms, or to deactivate the LB/KG button, please contact Technical Support at 1.800.638.3722. NO. DESCRIPTION FUNCTION 1. ON/OFF Turns scale ON and OFF. 2. ZERO Zeros the scale prior to weighing. 3. HOLD/RELEASE Holds the value of the weighed object on the display until the button is pressed again to clear the value. 4. KG/LB button Toggles between kilograms or pounds. 5. UP ARROW Scrolling method for entering height 6. BMI Prompts entry of data to calculate the patient’s Body Mass Index (BMI). 7. DOWN ARROW Scrolling method for entering height 8. 9. CLEAR ENTER Functions as menu escape in BMI mode Used to accept height in BMI mode 4 GENERAL This section provides instructions for maintenance, cleaning, troubleshooting and operator replaceable parts for the Physician Digital Scale. Maintenance operations other than those described in this section should be performed by qualified service personnel. MAINTENANCE B e f o re first use and after periods of non-use, check the scale for proper operation and function. If the scale does not operate corre c t l y, refer to qualified service personnel. 1. Check overall appearance of the total scale for any obvious damage, abuse, etc. 2. Inspect condition of AC adapter cord and prongs, replace if needed. CLEANING Proper care and cleaning is essential to ensure a long life of accurate and effective operation. Disconnect the scale from the AC power source 1. Clean all external surfaces with a clean damp cloth or tissue. Mild soap and water solution may be used. Dry with a clean soft cloth. 2. Do not immerse the scale into cleaning or other liquid solution. 3. Do not use Isopropyl Alcohol or other solutions to clean the display surface. TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on 1. Battery 2. Bad Power Supply (Plug power source into display module, check LED light at back of display module to determine if adapter cord is working) 3. Load cell cable is plugged into Communication port 4. Faulty electrical outlet 1. Replace batteries 2. Replace adapter 3. Switch load cell cable to Load cell port 4. Use a different outlet Questionable weight or the scale does not zero 1. External object interfering with the scale 2. The display did not show ‘000.00 before weighing 3. Scale is not placed on a level surface 4. Scale is out of calibration 1. Remove interfering object from the scale 2. Ask the patient to step off the scale. Zero the scale and begin weighing process again. 3. Place scale on level surface 4. Check weight with known weight value The display shows “OVER” The load on the scale exceeds the capacity (500lbs) Remove weight, turn scale off, then turn on and try again The display shows “LO Bat” message The batteries are low Replace batteries according to instructions ERROR LIST ERROR NO. DEFINITION CHECK/REPLACE Err 1 Mathematical mistake; division by zero. Cannot calculate calibration factor Will show when trying to calibrate with no calibration weight. Err 2 Insufficient weight during calibration While in calibration procedure add more weight in load mode Err 3 Unstable weight. Cannot calibrate. touches them and the cables are well soldered Check the load cells mechanical surroundings and see nothing Err 4 Keypad failure Check the connection of the keypad to the board connector. If the problem persists replace the keypad Err 5 Calibration jumper placed Take out the jumper from the PCB to enable calibration Err 6 High saturation state (high A/D) The load cell is not connected properly. Check the cables, and mechanical connection. If the problem persists, replace the set of load cells Err 7 Low saturation state (low A/D) See Err 6 CALIBRATION PROCEDURE The calibration procedure may be performed using a known weight in either kilograms or pounds. Simply set the scale for the desired unit of measure using the KG/LB key and start the calibration procedure. The following instructions assume the scale is set to measure lbs. The calibration is performed using kg or lb, according to the unit of measure used upon entering into the calibration path. Note: The calibration weight must be no less than 60 lb (28 kg) and no more than 300 lb (135 kg). 5 OPERATOR ACTION DISPLAY Turn the scale on. While “START” is displayed on the LCD (for 3 seconds) press the ZERO-KG/LB-KG/LB-ZERO keys one at a time on the keypad. “CAL” will a...

Dieses Handbuch ist für folgende Modelle:
Waagen - PROFESSIONAL 597KL (659.93 kb)
Waagen - PROFESSIONAL 752KL (659.93 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien