Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Dacor, modell 155 D

Hersteller: Dacor
Dateigröße: 978.31 kb
Dateiname: 264900EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2) Move the lever F to position A — Fig. 3. When connecting up the hood using a telescopic wall pipe, you should preferably using the uninflammable outlet hose No. E 610 899 007 (120 mm 0) from our range of special accessories. Extractor version 23 Filter version The air is filtered and recirculated through the front grille. You will need an original AEG KLF60/80 activated carbon filter for filtering function. (See special accessories). 24 Electrical connections Check that the power supply voltage shown on the rating plate Safety corresponds to the mains supply before proceeding to make any warnings for electrical connections. If the unit is supplied ready-fitted with a electrician plug, it can be connected to any easily accessible socket installed in compliance with the regulations in force. If a fixed connection is required, the hood must be installed exclusively by an electrician registered with the local electrical company. The hood should be installed using an omnipolar switch with contacts that open to at least 3 mm. Fused switches can be used for this purpose (with cartridge fuses that can be extracted from the fuse holder), as can automatic circuit breakers and contactors which open to more than 3 mm. We decline all responsibility for any problems or faults caused by a failure to observe the above instructions. Installing the socket directly above the hood or above the wall unit mounted above the hood offers the following advantages: 1. The socket cannot be seen. 2. The unit can be disconnected whenever required by simply taking out the plug. Electrical connections 230 V - using fixed power supply line with plug. (The unit should only be connected up by an authorized electrician). 25 Specifications Dimensions: Height Width Depth (in mm) 152 599 505 Weight: Net: 10,5 Kg Gross: 11,5 Kg Maximum absorbed power: 360 W Motor absorption: 2 x 140 W Lighting: 2 x 40 W Fan powers (levels), levels in compliance with DIN 44971 Exhausting version: min. 120 m3/h max. 254 m3/h Intensive speed 385 m3/h Recycling version: min. 50 m3/h max. 180 m3/h Intensive speed 206 m3/h Extractor system: 120 mm 0 Montage When used as an extractor unit, the hood must be fitted with a 120mm diameter hose. If the outlet hose is installed in a horizontal position, it must nevertheless be slanted at an angle of 10° so that the air can flow outside without impediment. If the cooking vapour is passed through an outside wall, you will need a telescopic wall pipe No. E 610 899 004 (120 mm 0) from our range of special accessories. When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ ring surfaces: electric cookers 650 mm gas cookers 650 mm coal and oil cookers 700 mm min. The hood cannot be connected to flues of other appliances that run on energy sources other than electricity. It is advisable to apply for authorization from the relevant controlling authority when connec...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - 155 D (978.31 kb)
Ventilatoren - 155 D (978.31 kb)
Ventilatoren - 155 D (978.31 kb)
Ventilatoren - 155 D (978.31 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien