5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. This unit must be grounded. CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. If ventilator is installed in an unconditioned space (such as an attic): Surround the ventilator with thermal insulation - to minimize possible condensation. 4. Please read specification label on product for further information and requirements. PLAN THE INSTALLATION Adequate ventilation requires that both intermittent and continuous contamination be controlled. Intermittent ventilation must be provided in the bathroom and kitchen. The bathroom requires 8 air changes per hour. (Multiply bathroom sq. footage by 1.1 for proper fan sizing). The kitchen requires a minimum of 150 CFM capacity (71 l/s) when a ducted range hood is used. If a kitchen fan is used, determine fan capacity by multiplying the room's sq. footage by 2. All are run intermittently to control pollution at the source. Continuous ventilation, while the house is occupied, provides the flow of fresh air for good indoor air quality. RECOMMENDED VENTILATOR SIZING (include finished basement area) DWELLING SIZE RANGE (Sq. Ftg.) MODEL .50 AC/HR* .35 AC/HR* .30 AC/HR* MP100 MP140 MP200 1500 2100 3000 2140 3000 4285 2500 3500 5000 *AC/HR = Air Changes per Hour. Based on 8' ceilings. Square Feet x .093 = Square Meters This ventilator is intended for continuous operation, supplying fresh air to the entire house. STALE AIR VENTILATOR FRESH AIR INLET AIR FLOW IN TYPICAL INSTALLATION DIFFUSER FRESH AIR INLET AIR FLOW IN TYPICAL INSTALLATION DIFFUSER PLAN THE INSTALLATION LOCATION OF DIFFUSERS & INLETS FRESH AIR VENTILATOR The ventilator exhausts stale air. There are normally sufficient natural intake openings into a dwelling to admit fresh outside air to be drawn in to replace the stale air. For better control, fresh air inlets may be used. The ventilator should be centrally located to keep ductwork as short as possible. Locations for the ventilator include: joists in an attic space or the basement, or a wall away from the living areas. EXHAUST DIFFUSERS (Available separately) Exhaust diffusers regulate the flow of fresh air drawn through the house. Exhaust diffusers should be mounted in the ceilings or high on the wall. For best performance, exhaust diffusers should be mounted in a central location. An exhaust diffuser should not be installed near a cooking area. (see figure) Cooking Equipment Do not install above or inside this area 45o 45o Floor COOKING AREA FRESH AIR INLETS (Available separately) For best control of fresh air in a room, install a fresh air inlet. The number of inlet vents depends on the floor plan. Consider the rooms/areas through which fresh air should flow toward the exhaust diffuser(s). Vents should be located in outside walls, preferably near the ceiling and approximately the same distance from a diffuser. Vents should be separated from diffusers far enough to allow fresh air to mix with room air before being exhausted. SINGLE-STORY HOME FRESH AIR INLETS DIFFUSER DIFFUSER BATH FAN DUCTED DUCTED KITCHEN RANGE HOOD FRESH AIR INLETS TWO-STORY HOME FRESH AIR INLETS FRESH AIR INLETS SECOND FLOOR DIFFUSER DIFFUSER BATH FAN DUCTED DIFFUSERDIFFUSER FIRST FLOOR FRESH AIR INLETS DUCTED KITCHEN RANGE HOOD BATH FAN DUCTED ON/OFF SWITCH WIRING ADAPTER PLATE BLACK WHITE BLACK BLACK BLACK WHITE BLACK BLACK INSTALL FRESH AIR INLETS 1. Mount all fresh air inlets in chosen locations during rough-in construction. Follow directions packed with inlets. MOUNT THE VENTILATOR CEILING JOISTS OR FRAMING CEILING JOISTS FRAMING 1. Add framing to ceiling joists as shown. 2. Set v...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - MP100 (210.84 kb)
Ventilatoren - MP200 (210.84 kb)