Locations for the ventilator include: joists in an attic space or the basement, or a wall away from the living areas. EXHAUST DIFFUSERS (Available separately) Exhaust diffusers regulate the flow of fresh air drawn through the house. Exhaust diffusers should be mounted in the ceilings or high on the wall. For best performance, exhaust diffusers should be mounted in a central location. An exhaust diffuser should not be installed near a cooking area. (see figure) Cooking Equipment Do not install above or inside this area 45o 45o Floor COOKING AREA FRESH AIR INLETS (Available separately) For best control of fresh air in a room, install a fresh air inlet. The number of inlet vents depends on the floor plan. Consider the rooms/areas through which fresh air should flow toward the exhaust diffuser(s). Vents should be located in outside walls, preferably near the ceiling and approximately the same distance from a diffuser. Vents should be separated from diffusers far enough to allow fresh air to mix with room air before being exhausted. SINGLE-STORY HOME FRESH AIR INLETS DIFFUSER DIFFUSER BATH FAN DUCTED DUCTED KITCHEN RANGE HOOD FRESH AIR INLETS TWO-STORY HOME FRESH AIR INLETS FRESH AIR INLETS SECOND FLOOR DIFFUSER DIFFUSER BATH FAN DUCTED DIFFUSERDIFFUSER FIRST FLOOR FRESH AIR INLETS DUCTED KITCHEN RANGE HOOD BATH FAN DUCTED ON/OFF SWITCH WIRING ADAPTER PLATE BLACK WHITE BLACK BLACK BLACK WHITE BLACK BLACK INSTALL FRESH AIR INLETS 1. Mount all fresh air inlets in chosen locations during rough-in construction. Follow directions packed with inlets. MOUNT THE VENTILATOR CEILING JOISTS OR FRAMING CEILING JOISTS FRAMING 1. Add framing to ceiling joists as shown. 2. Set ventilator in place and screw to framing with screws provided. Ventilator may also be hung from joists or rafters with hanging straps (available separately). CONNECT DUCTWORK 4" ROUND INSULATED FLEXIBLE DUCT DUCT TAPE OR CLAMP 6" ROUND INSULATED FLEXIBLE DUCT (OUTLET) FROM DIFFUSERS FROM DIFFUSERS TO ROOF OR WALL CAP 1. Run 4" insulated, flexible ductwork from ventilator inlet to diffuser location(s) and 6" insulated flexible ductwork from ventilator outlet to roof or wall cap.Outlet side is marked with a label. 2. To minimize condensation inside of ductwork in the attic, cover ductwork with additional insulation. Also, avoid forming condensation traps in the ductwork runs. 3. Seal ductwork to ventilator and roof or wall cap with duct tape or clamp (available separately). 4. If some ventilator inlets will not be used:Place the inlet cover(s) (provided) over the unused inlet(s) and tape them in place. WIRE THE VENTILATOR WARNING: DISCONNECT POWER AT SERVICE ENTRANCE AND LOCK OUT SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY. GROUND WIRE GROUND (Green or Bare Wires) 120 VAC LINE IN Use an ON/OFF switch to control the in-line ventilator. Accessory timers and humidity controls are also available. 1. Remove the wiring adapter plate. 2. Attach power cable to wiring adapter plate using U.L./ CSA approved connector. 3. Connect black to black, white to white, and green or bare wire to green ground screw. 4. Replace wiring adapter plate. Make sure tab on housing slides through slot in plate. 6 10 11 12 13 12 14 16 17 9 8 15 7 5 2 3 4 18 15 1 15 15 10 11 12 13 12 14 16 17 9 8 15 7 5 2 3 4 18 15 1 15 15 INSTALL EXHAUST DIFFUSERS USE AND CARE ** Not shown assembled. Always order replacement parts by “Part No, - not by “Key No.” BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge,...
Dieses Handbuch ist für folgende Modelle:Ventilatoren - MP140 (210.84 kb)
Ventilatoren - MP200 (210.84 kb)