Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Best, modell 860 D

Hersteller: Best
Dateigröße: 574.54 kb
Dateiname: 219500EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Indications in case of faults 148 Safety instructions For the electrical installer For the kitchen furniture installer Arrangement of the protective contact plug socket inside the chimney cover plate (Fig. EO/2) confers two advantages: 1. The plug socket is not visible. 2. You can easily de-energize the appliance where necessary by unplugging it. For the necessary fixed connection, the fume extractor hood may be connected only by an electrical installer registered with the electricity board covering your area. An isolating device is to be provided on the fixed wiring side. Switches with a contact opening of more than 3 mm also apply as isolating devices. These include line protection switches, fuses, and contactors (VDE 0730, s. 7, Part 1). Connection 220 V~ via fixed supply lead with protective contact plug (Eu-ropa version). 240 V~ via fixed supply lead (UK). (Fixed connection to be made only by an approved electrical installer) This appliance complies with the radio interference suppression requirements of EC Directives 76/889 EC and 82/499 EC. The exhaust air may not be introduced into a smoke flue or exhaust gas chimney. Introduction of the exhaust air into a shaft used for ventilation of the installation spaces of firerooms is not permitted. If the exhaust air is introduced into a non-operational smoke flue or exhaust gas chimney, it is advisable to seek the consent of the competent chimney-sweep. The official exhaust air guidance regulations are basically to be complied with. During operation as an exhaust air appliance, an adequate supply air opening of approximately the same size as the exhaust air opening is to be ensured. According to the Provincial Building Regulations, the joint operation of fume extractor hoods and chimney-linked fireplaces, such as coal- or oil-fired ovens and gas heaters, in the same space is subject to specific restrictions. In such spaces, the Fireplace Regulations only allow an underpressure of max. 0.04 mbar. The safe joint operation of chimney-linked appliances and fume extractor hoods is only guaranteed if space and/or dwelling (space/air interaction) are externally ventilated by a suitable supply air opening of around 500—600 cm2 and an underpressure thereby avoided when the fume extractor hood is running. SIE2 5/90 - SIKM1 11/89 GB/EU SIKM1 11/89 - SIKM3 5/90 GB/EU In doubtful cases, please seek the advice and consent of the competent area chimney-sweep or the local building authorities. Since, in spaces without fireplace, the rule is: “Supply air opening as large as exhaust air opening”, the efficiency of the exhaust air device may be impaired by the greater opening of 500-600 cm2. Operation of the hood as a return air hood in such circumstances is safe and is not subject to the regulations noted above. Operation of the fume extractor hood in return air mode is optimum only when the following are ensured: — short, straight exhaust air runs — as few pipe bends as possible — ru...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - 860 D (574.54 kb)
Ventilatoren - 8609 D (574.54 kb)
Ventilatoren - 8609 D (574.54 kb)
Ventilatoren - 8609 D (574.54 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien