Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung AEG, modell DD 8890

Hersteller: AEG
Dateigröße: 818.47 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Fig. I. • In order to obtain the best performance the hose should have a diameter equal to the outlet hole. Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/125 mm reduction flange provided. In this case the hood will be slightly noisier. Filter Version • The air is filtered through a charcoal filter and returned to the kitchen. • You will need an original AEG charcoal filter for the filtering function. (See Special Accessories). • Optionally, the position of the chimney elements can be changed. When using the hood in the filter version the chimney must be fixed at the top, with the air outlet grill at the side. 55 Control Panel • Best results are obtained by using a low speed for normal conditions and a high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking, you will then get an under pressure in the kitchen. The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared. The control switches are located on the unit’s front panel. CD ft go o„o„ A 1-2-3 ■ I A mln I 2 ab 3 4 5 6 Fig. 2 1 - Mains switch, ON/OFF Press for less than 1 1/2 seconds and the cooker hood goes into the "stand by" position (point "b" is illuminated). Press for more than 1 1/2 seconds and the cooker hood turns off, ALL the controls (except the light push button) are disabled (the display is off). Press again for more than 1 1/2 seconds to reset the cooker hood to "stand by". 2 - Light ON/OFF 3 - Display 4 - Start and choice of motor speed 1-2-3-1-2......... 5 - Intensive speed on/off. The Intensive speed runs for 5 minutes: If the hood is on when the Intensive speed is activated, the hood will revert to previous speed after 5 minutes. If the hood is off when the Intensive speed is activated, the hood will automatically turn off after 5 minutes. To interrupt the Intensive speed, press button I or 4. The letter P appears on the display and the remaining time (the point “a” is flashing), if interrupted an acoustic signal is heard. 6 - Self-Timer: times all the speed levels (the point “b” is flashing), and then the cooker hood switches off: The self-timer is set as follows: Ist speed level 20 minutes 2nd speed level IS minutes 3rd speed level 10 minutes The display shows the remaining operation time, at the end of the time an acoustic signal is heard. Depressing the push-button again exits the function. Should the hood or the controls fail to operate: disconnect the power supply for at least 5 seconds. After reconnecting the power supply wait 15 seconds and then check that the cooker hood is now operating correctly. 56 Control device for grease and charcoal filters This hood is fitted with a device that signals when it is necessary to clean the grease filter or the charcoal filter (if the hood is used in the recirculation version with a charcoal filter). On delivery, the hood is not supplied with a charcoal filter, so the saturation indicator will be disabled. If the hood is to be used with a charcoal filter, the saturation indicator light must be enabled as follows: Press buttons 4 and S simultaneously and hold them for 3 seconds. At first only the grease filter LED F will illuminate, but when the charcoal filter LED C illuminates the saturation indicator will be enabled. To disable it: Press buttons 4 and S again simultaneously and hold them for 3 seconds, until the charcoal filter LED C goes out. Grease filter LED (F) LED F will start to flash when it is time to clean the grease filter. Cleaning will be necessary after 40 working hours. Always comply with the maintenance instructions for the grease filter. Charcoal filter LED (C) The charcoal filter LED C will start to flash when the charcoal filter needs to be replaced. This operation is necessary after approximately 160 working hours. Resetting the saturation indicator After cleaning or replacing the filters, press button I for 3 seconds until the grease filter LED F or the charcoal filter LED C stops flashing. Warning! The resetting of the saturation indicator MUST be done in stand-by, never disconnect the hood from the mains. 57 Maintenance and care • The hood must always be disconnected from the electricity supply before beginning any maintenance work. Cleaning the hood • Clean the outside of the hood using a damp cloth and a mild detergent. • Never use corrosive, abrasive or flammable cleaning products. • Never insert pointed objects in the motor’s protective grid. • Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. • Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents. • It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute ...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - CHDD 8820 (818.47 kb)
Ventilatoren - CHDD 8890 (818.47 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien