Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Hunter Fan, modell 82005

Hersteller: Hunter Fan
Dateigröße: 3.82 mb
Dateiname: 41948.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


You should replace the impeller at the same time. 41948-01 3/29/2006 2 05-HF-019-EngS_3.29.06.indd 2 3/29/06 7:06:40 PM x2 3/8” Cable Connector E F G H I J K L x4 * * * NOTE: Strain relief cable connector must be installed. Not Included. A B C 95047-06-000 75864-01-000 03242-07-133 95261-01-000 74508-03-133 96382-01-262 75184-01-133 96386-01-000 M 75733-03-306 x2 D Extra Screws 3 1 Turn off the power source. Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes Before Installation Check all the parts. If damaged, call 1-888-830-1326 for replacements. 2 E I Loosen screws. NOTE: Remove all packing materials before installation. 41948-01 3/29/2006 Included. 05-HF-019-EngS_3.29.06.indd 3 3/29/06 7:06:42 PM 5 4 7 G 8 F Remove the motor/blower from the housing. 4 H E 3 Remove the pre-loaded screw tip covers. Remove the wiring cover screw. 6 Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover. Remove packing material. 41948-01 3/29/2006 05-HF-019-EngS_3.29.06.indd 4 3/29/06 7:06:44 PM 9 E Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction 5 10 B C Choose Installation Option For New Construction - go to step A11, page 5 For Existing Construction - go to step B11, page 8 A11 E 5/8 1/2 5/8 1/2 A12 Screw pre-loaded screws into joist or framing. 41948-01 3/29/2006 05-HF-019-EngS_3.29.06.indd 5 3/29/06 7:06:46 PM A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A14 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option A13 Route wires through the strain relief. Connect wires as shown. A016 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. 6 A15 E F G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 41948-01 3/29/2006 05-HF-019-EngS_3.29.06.indd 6 3/29/06 7:06:48 PM A19 I Secure the motor by tightening the 2 screws. A20 Turn on the power source. 7 Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. A17 0 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 0 H A18 ON OFF A21 Test the motor. If the motor does not run, check the plug connection. A22 C1 Go to step on page 10 to attach grille. 41948-01 3/29/2006 05-HF-019-EngS_3.29.06.indd 7 3/29/06 7:06:51 PM B11 EXISTING FAN E B12 Existing Construction B13 2 1 B14 Route wires through strain relief. Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7 1/2”x 7 3/4”). Move the housing into position above the ceiling Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. E B15 Screw pre-loaded screws into joist or framing. 8 41948-01 3/29/2006 05-HF-019-EngS_3.29.06.indd 8 3/29/06 7:06:54 PM A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B16 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option H B18 H B19 B20 I Connect wires as shown. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Secure the motor by tightening the 2 screws. F B17 G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 41948-01 3/29/2006 9 05-HF-019-EngS_3.29.06.indd 9 3/29/06 7:06:56 PM ON OFF B22 B23 C1 Go to step on page 10 to attach grille. B21 Test the motor. If the motor does not run, check the plug connection. Turn on the power source. Attaching the Grille Remove the thumbscrews. Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. K C1 C2 J 10 41948-01 3/29/2006 05-HF-019-EngS_3.29.06.indd 10 3/29/06 7:06:59 PM Install 2 Max 60 watt A-15 bulbs (Not Included). Align glass dome and push up. C7 M Screw finial into position. C5 C6 L Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. K C4 Align posts 1, 2 and 3 (stamped into motor housing) with posts 1, 2 and 3 (stamped into light fixture). Slide light fixture over posts. J C3 41948-01 3/29/2006 11 05-HF-019-EngS_3.29.06.indd 11 3/29/06 7:07:02 PM Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien