Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Desa, modell (V)KC36PE SERIES, (V)KC36NE SERIES

Hersteller: Desa
Dateigröße: 2 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Horizontal High Wind Square Termination Screws 45° Elbow Wall Firestop Wall Firestop Maintain 1" Minimum Air Space Around Outer Pipe When Penetrating a Wall High Wind Termination Square Termination Vertical (V) Horizontal (H) 32 3/4" min. 17" max. Apply Mastic to Outside Edge of Standoff 10 3/4" x 10 3/4" Framed Opening 45° Elbow Exterior Portion of Wall Firestop (Round Termination Only) Exterior Wall with Vinyl Siding Wall Firestop Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed Horizontal Termination Configurations Figures 14 through 18 show different configurations and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: If using a venting configuration of only horizontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required. NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance. WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. Horizontal Round Termination Round Termination * If installing this fireplace at altitudes of 4000 feet and above, it is recommended that an additional vertical height of 6" be added to the vent system. Figure 14 - Horizontal Termination Configuration for Square or Round Terminations CORNER INSTALLATION Recommended Applications: • Corner ground floor installation • Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe) • Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications: • Installations requiring a vertical rise on building exterior • Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill around snorkel termination. Venting Installation instructions Continued Not to Exceed (H) Limits Square Termination 90° Elbow Wall Firestop 90° Elbow 12" Min. Not to Exceed (H) Limits Square Termination As Required for (V), See Chart for Pipe Section Required 45° Elbow Wall Firestop Required Vertical (V) Vertical Pipe Horizontal (H) *43 1/2" min. None 30" max. 54 1/2" min. 1 ft. 48" max. 66 1/2" min. 2 ft. 60" max. 78 1/2" min. 3 ft. 84" max. 90 1/2" min. 4 ft. 20' max. * Ground Floor Corner Venting 45° Elbow Figure 15 - Horizontal Termination Configuration for Corner Installation Using One 90° Elbow Snorkel Termination Wall Firestop Snorkel Termination Snorkel Termination 90° Elbow 12" Min. 12" Min. 12" Min. 45° Elbow Adequate Drainage Figure 16 - Snorkel Termination Configurations for Below Ground Installation Venting Installation instructions Continued HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows. 45° Elbow Venting with Two 90° Elbows Vertical (V) Horizontal (H1) Horizontal (H1) + Horizontal (H2) 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' max. 20' max. 20' max. 8' max. 20' max. Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows Venting with Two 90° Elbows Vertical (V) Horizontal (H1) + Horizontal (H2) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. 20' max. 20' max. 45° Elbow Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows with Termination at 90° with Fireplace Venting Installation instructions Continued installation for vertical termination Note: Vertical restrictor must be installed in all vertical installations. 1. Determine the route your vertical venting will take. If ceiling joists, roof rafters or other framing will obstruct the venting system, consider an offset (see Figure 19) to avoid cutting load bearing members. Note: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum vertical rise of the venting system and any maximum horizontal offset limitations. 2. Set the fireplace in desired location. Drop a plumb line down from the ceiling to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point. Drop a plumb line from the inside of the roof to the locating hole in the ceiling. Mark the center point where the vent ...

Dieses Handbuch ist für folgende Modelle:
Kamine - (V)KC36NE Series, (V)KC36PE Series (2 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien