Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Hunter Fan, modell PERFECT WINDOW HR200

Hersteller: Hunter Fan
Dateigröße: 233.88 kb
Dateiname:

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


if the system includes an optional remote control, switch it to the ON position. NOTE: To set the dehumidistat, refer to the previous section of this booklet. To operate other remote devices, refer to the device owner.s manual. 69-0994.4 6 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS WARNING Electrical Shock Hazard. Can cause personal injury or equipment damage. Disconnect power supply before performing maintenance. The Perfect Window. Fresh Air Ventilation System must be maintained on a regular basis for best efficiency. Honeywell recommends that the ventilator be cleaned and checked at least twice a year, preferably at the beginning of each heating and cooling season. Check and Clean EXTERIOR HOODS Exterior hoods should be inspected at least once a month. Be sure exhaust and fresh air supply hoods are not blocked up or restricted by leaves, grass or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen). WARNING Can cause personal injury or equipment damage. Hood blockage can cause a change of pressure in building which can lead to possible spillage from combustible appliances. AIR FILTERS Air filters should be cleaned twice a year. The standard filters supplied with your ventilator are removable and washable. 1. Open access door and slide out core. Refer to Core Maintenance section for cleaning instructions. 2. Remove filter clip. 3. Remove filters from the core and rinse with water or a combination of soap and water. Do not clean in a dishwasher. 4. After cleaning, place filters (wet or dry) back in their position and reattach the retaining clip. 7 69-0994.4 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Clean the core twice each year. FILTER CLIP FILTER 1. Open the access door and carefully grip the ends of the core and pull evenly outward. The core can be snug, but it will slide out of the cabinet. NOTE: Do not handle the fins because damage can occur. 2. Once out of the cabinet, remove the filters (refer to Air Filter Maintenance section). 3. Wash the core in warm soapy water.do not use a dishwasher. 4. Reinstall the clean filters. 5. Reinstall the clean core. NOTE: Do not detach the foam on the ends of the core or the core label, water does not damage them. To install the clean core: 1. First mount the bottom core guide into the bottom H channel. 2. Mount either side core guide, followed by the other side. 3. Mount the top core guide into the top H channel. 4. With all four comers in place and the core straight and even, push on the core center until the core slides to the back of the cabinet. NOTE: The core will appear to stick out from the cabinet approximately 1/8 in. (3mm). It is designed this way, so that the access door will fit tightly against the core. MANUAL CONTROL MODEL CORE GUIDE M11702A 69-0994.4 8 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Clean the drain line once a year. 1. Inspect the drain line, drain spout and P trap for blockage, mold or kinks. 2. Flush with warm soapy water and replace if worn or bent, or if it can not be cleaned. GENERAL MAINTENANCE Twice a year wipe down the inside of the cabinet with a damp cloth to remove dirt, bugs and debris that can be present. FANS If the fans accumulate dirt, it could cause an imbalance and excessive vibration of the ventilator. A reduction in air flow can also occur. In a newly constructed house, this often happens within the first year due to heavy dust residue in the entire system. It can also occur periodically depending on the outdoor conditions. If you suspect that service is required, please contact the ventilator installer or your local HVAC contractor. 9 69-0994.4 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Describing Perfection The most convenient, most energy efficient, cleanest, healthiest and most comfortable indoor environment, possible today! Perfect climate is achieved when the six core components of your homes climate system work together: • optimal efficiency of heating and cooling equipment • precise, programmable temperature control • effective indoor air quality control • controlled humidity • proper ventilation and air distribution • zone control for personalized room-to-room temperature control. Products for a Perfect Climate® Home HEATING AND COOLING SYSTEM This is the workhorse of ...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - PERFECT WINDOW HR150 (233.88 kb)
Ventilatoren - PERFECT WINDOW HR150 (233.88 kb)
Ventilatoren - PERFECT WINDOW HR200 (233.88 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien