Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Honeywell, modell PERFECT WINDOW HR150

Hersteller: Honeywell
Dateigröße: 233.88 kb
Dateiname: ad13cf9d-eb2d-4848-a5c1-47e0ef694e68.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Feeling right at home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 What your Perfect Window. Fresh Air Ventilation System consists of . . . . . . . . . . .4 Operating your Fresh Air Ventilation System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Getting the most from your Fresh Air Ventilation System. . . . . . . . . . . . . . . . . . . . . .7 Maintenance of your Fresh Air Ventilation System. . . . . . . . . . . . . . . . . . . . . . . . . . .8 Perfect Climate® Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 69-0994.4 2 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS We take it for granted that our homes will protect us from the elements, but because of tighter, better quality home construction, our indoor environment may be exposing us to unacceptable levels of the very things we are trying to escape. Excessive heat, dryness, humidity, toxic gases and dust contaminants can be sealed in securely by weatherproofing. So what.s the forecast for indoors? Today.s indoor forecast is stormy weather for many homeowners. But rapid clearing and fresh breezes are just around the corner! Feeling right at home Unlike what the outdoors brings us, you can have control of indoor conditions. Temperature, humidity levels and air quality can all affect physical health, mental attitude, general comfort and energy savings. With today.s technological advances, you can achieve a .Perfect Climate. indoors. After all, people look to their homes as a place to escape the stress of work, a busy lifestyle and an increasingly polluted outdoor environment. Creating a perfect indoor climate is becoming critical to feeling right at home. The Honeywell Perfect Window. Fresh Air Ventilation System removes stale, unhealthy air and replaces it with a stream of fresh air. Its powerful centrifugal blowers bring fresh air into your home and at the same time, exhaust stale humid air in an equal amount. Both incoming and outgoing airstreams pass through a heat exchange core where the energy from the exhaust air is efficiently transferred to the incoming fresh air. An air duct system supplies the fresh air brought in by the Perfect Window. ventilator and distributes it throughout your home. Another duct draws the existing stale, humid air back to the Perfect Window. ventilator and then exhausts it outdoors. It.s really very simple ... and remarkably effective! What your Perfect Window. Fresh Air Ventilation System consists of ... 1. Air Circulation Pan and Motor Inside the casing are two fans, one for exhaust and one for fresh air supply. The electric motor that operates the fan is 1/15 hp to 1/20 hp (depending on the ventilator model) and uses the same amount of power as a 100 watt lightbulb. 2. Air Filters There are two permanent washable air filters in your ventilator. The filters lower the amount of dust and outside particulates entering the ventilator core and your fresh air supply. 3 69-0994.4 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS . Condensate Tray and Drain Condensation normally forms on the heat exchange core during the cold weather (below 29°F or -2°C). Moisture can build up when the warm air from your home comes in contact with the cold air from outside. The tray collects the moisture and funnels it to the drain. The drain pans are made of therrnoformed plastic for easy cleaning. 4. Defrost Mechanism The built-in defrost mechanism will remove frost which can accumulate in colder weather (21°F [-6°C] and colder). The type of defrost mechanism used is known as .damper style.. This consists of an electronically controlled damper door (attached to a small electric motor) that moves to block off the outside cold air entering the ventilator. If the outside temperature drops below 27°F (-3°C), the defrost timer is activated. The timer activates the motor driven damper door mechanism which temporarily moves to close off the outdoor air supply and opens another port on the ventilator...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - PERFECT WINDOW HR150 (233.88 kb)
Ventilatoren - PERFECT WINDOW HR200 (233.88 kb)
Ventilatoren - PERFECT WINDOW HR200 (233.88 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien