Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung NuTone, modell IKD 1157.1 GE-UL

Hersteller: NuTone
Dateigröße: 697.51 kb
Dateiname: f34ad1a6-003f-4a8e-983d-3094a701e284.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Your kitchen hood is designed for domestic use and only for extraction and purification of gases produced during food preparation. It will be your responsibility if it is used for other purposes, which may be dangerous. The manufacturer cannot accept responsibility for damage caused by improper use of the apparatus. • For repairs please contact the nearest KUPPERSBUSCH Technical Assistance Service, and always use genuine spare parts. Repairs or modifications effected by unqualified personnel can cause malfunctions or may damage the apparatus, putting your safety in danger. Index Page Description of the apparatus 3 Instructions for use 4 Programming timer 4 Cleaning and maintenance 4 Problem solving 5 Sizes and specifications 5 Accessories supplied 6 Grounding instructions 6 Installation 7 Active charcoal filters 8 A Electronic programmer control box with buttons to control speed, light and power in use indicators. B Metal filters. C Lamp with two lights - 20 W (G-4). D, E Vertically adjustable tubecovers. F Decorative part. ( No incluided ). 3 ENG Description of the apparatus Manual ND ISLA UL ing.qxd 6/05/2003 11:50 P.gina 3 Manual ND ISLA UL ing.qxd 6/05/2003 11:50 P.gina 4 Instructions for use You may control the kitchen hood's workings by operating the controls as shown in the diagram. ENG 321132 To improve draught we recommend to turn the extractor fan on a few minutes before cooking so that the flow of air is continuous and stable when fumes are extracted. Similarly, keep the extractor fan on for a few minutes after cooking to completely extract fumes and odours. Programming timer 1.- By pressing for more than 2 seconds any speed, the kitchen hood will stay switched on for 10 minutes at the selected speed. To program a duration other than 10 minutes: a).- With the kitchen hood switched off, press “timer”. b).- Select the required programming time by pressing the chosen button (see drawing). c).- Press “timer” again to record the new program. d).- Press the chosen speed for more than 2 seconds, the pilot light will start flashing. Cleaning and maintenance When cleaning and doing maintenance, make sure the safety instructions set out on page 2 are complied with. Cleaning the body of the kitchen hood • If your kitchen hood is made from stainless steel, use this material's specially designed cleaners following the instructions mentioned in the product supplier.s instructions. • Never use metallic scourers, nor abrasive or corrosive products. • Dry the kitchen hood using a cloth that does not produce fluff. Cleaning the metal filters To remove the filters from their fittings, press lightly on the locks and then pull them off. The metal filters can be cleaned by soaking them in hot water with neutral detergent until the fat dissolves and then rinsing them under the tap or using products specially designed for fats. They can also be washed in a dishwasher. In this case, it is advisable to stack them vertically to avoid food residue sticking to them. Cleaning in a dishwasher with aggressive detergents or polish may damage the metallic surface (blackening it), although this will not affect its fat retention capacity. Once clean, leave them to dry off and then fit them onto the kitchen hood. Changing lights Proceed as follows: • Unscrew the decorative element of the halogen lamp. • Change the broken/burnt out lamp. Maximum lamp power is 20 W (G-4). • Screw back on the decorative element of the halogen lamp. 4 Manual ND ISLA UL ing.qxd 6/05/2003 11:50 P.gina 5 Problem solving Proceed with the following checks before calling the Technical Service: Problem Possible cause Solution The extractor fan ceases to function The kitchen hood feed cable is not connected to the network. There is no electrical current in the network Connect feed cable to the network. Check that the network has electrical current The extractor ceases to educt strongly or vibrates Filters are saturated with fat. Obstruction in the air exit conduct Change or clean the active charcoal and/or metal filters, as the case may be. Eliminate the obstruction The lamps do not light up The lamps are burnt out The lamps are loose Change the lamps Tighten the lamps Sizes and specifications 3 2 1 ENG 5 6 ENG KUPPERSBUSCH reserves the right to make changes and corrections to its products as it deems necessary, without altering their basic characteristics. Technical Code Network Code (V) Network Frecuency (Hz) Lights/ Motor Power (W) Motor Volume 22UL324IS 120 60 2x20 / 340 850 m3/h C UL US Tec. Cod. ELECTRIC FAN LISTED XXXX © F .Nr********** Made in Europe 1 150/125 mm reduction. 1 Anti-recoil valve. 6 Lock screws (O8 x 45). • This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is plugged into an ou...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - IKD 1157.1 GE-UL (697.51 kb)
Ventilatoren - IKD 1157.1 GE-UL (697.51 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien