Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Greenheck Fan, modell KHTU160

Hersteller: Greenheck Fan
Dateigröße: 416.59 kb
Dateiname: fdbd121f-8b29-49bb-93bc-9758c11ca9cb.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If wall or roof vent system cap has a damper, DO NOT attach damper that came with hood. Non-vented (recirculating) installations only: Assemble the vent system you will use over the roof vent opening but do not attach the vent system yet. A Measure distance A and transfer it to the centerline on the soffit. Mark and cut a 3-1/4” x 10” (8.3 cm x 25 cm) vent opening in the soffit. 18.The hood is attached to cabinet bottom by four screws with washers inserted through cabinet bottom from inside of cabinet and into hood. • If your cabinet has a frame around the bottom, use the four 2-3/4" (7 cm) long screws in parts bag. • If your cabinet has a flush bottom (no frame), use the four shorter 2" (5.1 cm) long screws in parts bag. WARNING Excessive Weight Hazard Use two or more people to move and install range hood. Failure to do so can result in back or other injury. 19.Lift hood into place whilefeeding wiring into wiring box. Feed enough wire into wiring box to easily make the connections and tighten the strain relief. Insert the four screws through cabinet bottom and into hood. Start screws into hood and tighten securely. 20.Connect the vent system. Non-vented installations: Install the grille on the soffit. Electrical connection WARNING Electrical Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. green ground screw 21.Connect the white and black wires of power supply cable to the white and black leads in hood with twist-on connectors. Connect the power supply ground wire to the green ground screw inside hood’s terminal box. Replace terminal box cover. install screw tab 22.Reinstall light panel. Insert light panel tabs into slots. Push in on back of light panel and insert the small tabs into the locating holes in back of the hood. Reinstall the 2 screws and tighten securely. filter hub 23.Non-vented (recirculating) installations: Install the charcoal filters. Place filter over hub in blower openings, push up and turn clockwise to lock filter into place. 24.Install the aluminum grease filters. 6 Operation of range hood For best results, turn range hood fan ON at beginning of cooking and allow it to run until all smoke and odors are removed from the room. light fan To turn fan ON and OFF: Slide fan control to turn fan on and off and adjust fan speed. Speed may be increased or decreased anytime during range hood operation. To turn range hood light ON and OFF: Slide light control to turn on or off. Light may be turned on or off anytime during range hood operation. Deflector: When cooking will create a lot of smoke, use the deflector. The deflector will concentrate the venting action of the hood. To use deflector, grasp from inside and pull down. Push up to return to its original position. Use and Care Information WARNING — To reduce the risk of fire or electrical shock, do not use this fan with any solid-state speed control device. WARNING — TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a tag to the service panel CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. WARNING — ...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - KHTU160 (416.59 kb)
Ventilatoren - KHTU160 (416.59 kb)
Ventilatoren - KHTU160 (416.59 kb)
Ventilatoren - KHTU160 (416.59 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien