Anleitung Kuppersbusch USA, modell Kitchen Hoods

Hersteller: Kuppersbusch USA
Dateigröße: 237.11 kb
Dateiname: 57133e71-53c8-4797-9cbc-b41870226444.pdf
Unterrichtssprache:plen
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Dry the kitchen hood using a cloth that does not produce fibres. Problem solving To remove the filters from their fittings, press lightly on the locks and then pull them off (fig. 3). The metal filters can be cleaned by soaking them in hot water with neutral detergent until Cleaning in a dishwasher with aggressive detergents or polish may damage the metallic surface (blackening it), although this will not affect its fat retention capacity. Once clean, leave them to dry off and then fit them onto the kitchen hood. 3.3 Changing the light bulbs Proceed as follows: • Remove the metal filters. • Change the broken/burnt out lamp. Maximum lamp power is 40W. • Fit the metal filters. Problem solving Proceed with the following checks before calling Technical Services: Problem The extractor fan does not work. Possible cause The mains cable is not connected to the network. There is no current in the network. Solution Connect mains cable to the network. Provide current to the network. The kitchen hood does not extract sufficiently or vibrates. Filters are satured with fat. Obstruction in the air conduct. Change or clean the active charcoal and/or metal filters, as the case may be. Remove the obstruction. The lamps do not light up. The lamps are blown. The lamps are slack. Change the lamps. Tighten the lamps. 13 Gea-Top/001 UK 4. Sizes and specifications fig.4 4.1 Technical specifications Network tension (V) Network frequency (Hz) Lights/Motor Power (W) Motor Volume (m3 /h) 230 - 240 50 Hz 2x40 / 140 480 Dimensions fig.4 PAINTED STEEL A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) MIN MAX LARO 90 900 500 377 877 98 247 188 PAINTED STEEL A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) MIN MAX TRENTI 90 900 502 523 1023 98 218 157 PAINTED STEEL A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) MIN MAX VENTOLINE 60 600 502 488 988 122 157 218 VENTOLINE 90 900 502 494 994 122 157 218 PAINTED STEEL A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) MIN MAX NUBERO 60 600 504 488 988 98 152 142 NUBERO 90 900 510 483 983 98 152 142 TEKA INDUSTRIAL S.A. reserves the righ to make changes and corrections to its products as it deems 14 Gea-Top/001 necessary, without altering their basic characteristics. UK 5. Accessories supplied 1 120/150 mm reduction 2 wall support for tubecover 2 wall plugs (O9x40) 2 long bolts (O9x40) 6 wall plugs (O5x40) 6 long bolts (O5x40) 2 active carbon filters (optional) 6. Installation On installing the kitchen hood make sure thet Safety Instructions set out on page 14 are complied with. To obtain optimum performance, the external duct must not to be more than FOUR METERS LONG, have no more than two 90° angles and its diameter must be at least O120. 6.1 Installing: Trenti / Nubero / Ventoline fig.5 1. Mount the 150/120 reduction whenever the air discharge tube is O125 (fig.7); 2. Trace and drill the points for fitting the wall plugs (H O9x40) and (L O5x30) onto the wall at the desired height by leaning the hood on the wall, then tighten the long bolts (H); 3. Hang the kitchen hood, hooking its support (I) onto the long bolts (H) as in fig.5b and then tighten the long bolts (L); 4. Trace and drill the location of the lower support (G) of the tubecover, fit the wall plugs (M) and fix it by using the bolts (M), then hook the fixed chimney to its support (G) as in fig.5c; 5. Mount the mobile chimney and lift it up to the desired height and mark its shape on the wall; 6. Remove the fixed and mobile chimneys; 7. Centre the upper support (G) around the shape marked, trace and drill the fixing points for fitting wall plugs (M), then fix the support (G) by using bolts (M); 8. Attach the inner tube, possibly flexible, with a clamp (not supplied) to the motor’s air outlet or to the 150/120 reduction as the case may be (fig.7); 9. Once the inner tube is fitted, fit the fixed and mobile chimney around the extractor fan outlet and hook them onto respective supports; 10.Connect the scavenging pipe to the outdoor duct and fix it with a pipe tightening clamp. 6.2 Installing: Laro fig.6 1. Mount the 150/120 reduction whenever the ...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - Kitchen Hoods (237.11 kb)
Ventilatoren - Kitchen Hoods (237.11 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien