Login:
Stimmen - 2, Durchschnittliche Bewertung: 3 ( )

Anleitung Bosch, modell DHG6015DUC

Hersteller: Bosch
Dateigröße: 1.77 mb
Dateiname: DHD3014UC_IM.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


READ AND SAVE THESE INSTRUCTIONS WARNING To reduced the risk of fire, electric shock, or injury to persons, observe the following: A. Installation work and electrical wiring must be done by authorized person(s) in accordance with all applicable codes and standards, including fire- related construction. B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fired Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. Always unplug or disconnect the appliance from the power supply before servicing. F. This unit is designed for indoor use only. Use this unit only in the manner intended by the manufacturer. G. Make certain the cooktop is appropriate for use with a downdraft vent. H. Not intended for use with professional- style cooktops. WARNING For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. To reduced the risk of fire, use only metal duct work. To reduce the risk of fire, electric shock and injury to persons, Downdraft must be used with Internal, Remote or Inline Blower. To reduce the risk of fire or electric shock, do not use the fan with any solid- state speed control device. This appliance has been found to be in compliance with UL 507 Standard for Electric Fans and CAN/CSA-22.2 No. 113 Canadian Standard for Fans and Ventilators. It is the responsibility of the owner and the installer to determine if additional requirements or standard apply in specific installation. Parts Needed (standard) . Tape Measure . Phillips Head Screwdriver . Aluminum Duct Tape . Ductwork (configuration varies depending on location; See pages 7-12 for further information) . Additional Sheetmetal screws (as necessary for ductwork installation) . Saw (or equivalent for cutting counter- top) . #8 x 1 1/4” Wood Screws (4) . Plumb Bob . Wire to reach Remote or Inline Blower Parts Needed (special) . Special Blower . Transition Box (for use only with Inline and Remote Blowers) . Recirculation Module (used only for recirculation applications) Note: Downdrafts work with these blowers: 600 CFM Integrated, Remote or Inline Blowers 1000 CFM Remote or Inline Blowers Parts Supplied . Downdraft assembly (1) . #8 Sheetmetal Screws (8) . Blower Cord Strain Relief (1) . Hardware for brackets on vent (2) . Remote Blower Pigtail Downdraft - Unit Strain Relief Blower / Duct Transition Box (Not Included) Fig. 1 INTRODUCTION GENERAL DESCRIPTION The complete downdraft system consists of the downdraft, a blower and a transition box if using an Inline or Remote Blower. A recirculation module is also available when ducting to the outside is not preferred or not possible. (See Fig. 1). The blower can be either integral (mounted on the vent intake in the cabinet under the cooktop), an inline (mounted between the kitchen and exterior wall anywhere within the duct line), or a remote (mounted on the roof or outside wall). When a remote or inline blower is used, a duct transition is mounted on the ventilator intake in place of the integral blower to connect the intake to the duct work. The duct transition must be purchased separately. The integral blower or duct transition can be mounted in different positions on the intake to route ductwork to avoid cabinet, building framing, utilities, etc. The downdraft system is available in 30inch or 36- inch. Intended for non-professional style cooktops only. A Recirculation Kit can be purchased separately and used in conjunction with the Integral Blower if ducting to the outside is not a viable option. Step 1: Plan the installation Carefully follow the planning procedures listed below (See Figure 2). Sketches are NOT intended to be a replacement for careful planning. A. Determine whether a remote, inline, or integral blower will be used. Remote and inline blower installation requires 4 wires plus a ground wire to run from the downdraft to the blower. B. Make sure that adequate cabinet and counter space has been provided and that the intake and blower will be accessible if service is required. C. Consider that cross drafts created by adjacent open windows, doors, air conditioning, old heating vents, recessed ceiling lights, and traffic patterns may affect performance. D. For gas cooktop installations make sure that a minimum 10 square inch opening is provided in the toe-kick or other cabinet area. Inadequate ventilation of the c...

Dieses Handbuch ist für folgende Modelle:
Kochfelder - DHG601DUC (1.77 mb)
Kochfelder - DHG6023UC (1.77 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien