In a chimney stack or branched flue. Directly to the Outside(exclusively for cooking appliances) b)The room must have an air flow to allow for proper combustion. This must be 2 m3./h per kW of installed power. The airflow can be created using an enclosed vent with an inner cross section of at least 100 cm. which must not be able to be blocked. I the appliance does not have a flame failure device, the vent must have an internal cross section of 200 cm3. (Fig. A). Alternatively the room in which the hob is situated can be vented indirectly through ventilation ducts as specified above, as long as the adjacent room is not a shared area, a bedroom or present any risk of fire (Fig. B). Detail A Adjacent Room to be d) Liquidified petroleum gases are heavier than air and, as a result, settle downwards. Rooms in which LPG tanks are installed must be fitted with ventilation openings to the outside in order to allow the gas to escape in the event of a leak. Therefore, LPG tanks, whether empty or partially full, must not be installed or stored in rooms or spaces below ground level (cellars, ect.). It is also a good idea to keep only the tank currently being used in the room, making sure that it is not near sources of heat (ovens, fireplaces, stoves, etc.) that could raise the internal temperature of the tank above 50°C. Installation of Built-in Hobs The gas hob is equipped with type X degree protection against overheating. Therefore, the appliance can be installed next to cabinets, provided the height of the cabinet does not exceed that of the hob. For proper installation of the hob, the following guidlines must be followed: a) If the cabinet(s) located next to the hob are higher than the hob itself, the cabinet(s) must be installed at least 110 mm from the hob edge. b) Hoods must be installed in accordance with the instructions contained in the installation manual for the hoods themselves, and no less than 650 mm from the hob. c) In the case of the 600 mm cooker hoods, besides following the recommendations in point b), the cabinets should be positioned next to the hood at a height of at least 540 mm from the top since this will make it possible to install the lid and move it correctly.The cabinet should always be installed at a height from the top which allows easy use of pots and 700mm min. pans on the cooker. d) Should the hob be installed directly under a cupboard, the latter should be at least 700 mm (millimetres) from the top, as shown in Figure C. Fig. C 540mm min. 600mm min. A Room Vented e) The dimensions of the cutout for the appliance must be those indicated in the figure D. Clamps are provided to fasten the hob to counters measuring from 20 to 40 mm in thickness. To fasten the hob securely, it is recommended that all the clamps be used. Fig. D 55 mm Examples of ventilation holes Enlarging the ventilation slot for comburant air. between window and floor. Fig. A Fig. B c) Intensive and prolonged use of the appliance may necessitate supplemental ventilation, e.g. opening a window or increasing the power of the air intake system (if present). 555 mm 475mm 8 9 Gas Connection for the Hob The hob should be connected to the gas supply by an authorized installer. During installation of this product it is essential to fit an approved gas tap to isolate the supply from the appliance for the convenience of any subsequent removal or servicing. Connection of the appliance to the gas mains or liquid gas tanks must be carried out according to the safety standards currently in force, and only after it is ascertained that it is suitable for the type of gas to be used. If not, follow the instructions indicated in the section entitled, “Adapting the Hob for Different Types of Gas”. If the hob is to be connected to tanks containing liquid gas, use pressure regulators that comply with current safety standards. Important: To insure that the appliance operates safety, the gas is regulated correctly and your appliance lasts over time, make sure that gas pressure levels comply with the indications given in Table 1, “Nozzle and Burner Specifications”. Gas Connection to Non-flexible Pipe (copper or steel) Connection to the gas source must be done in such a way as to not create any stress points at any part of the appliance. The appliance is fitted with an adjustable, "L" shaped connector and a gasket for the attachment to the gas supply. Should this connector have to be turned, the gasket must be replaced (supplied with the appliance). The gas feed connector to the appliance is a threaded, male 1/2" connector for round gas pipe. Gas Connection to Flexible Steel Pipe The gas feed connector to the appliance is a threaded, male 1/2" connector for round gas pipe. Only use pipes, tubes and gaskets that comply with current safety codes. The maximum length of the flexible pipes must not exceed 2000 mm. Once the connection has been made, ensure that the flexible metal tube does not touch any moving parts and is not crushed. Check the Seal Onc...

Dieses Handbuch ist für folgende Modelle:
Kochfelder - S840G (398.1 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien