Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung DCS, modell GAS HOB 85600 G

Hersteller: DCS
Dateigröße: 130.35 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


France Senlis +33 (0)3 44 62 29 29 Germany Nurnberg +49 (0)911 323 2600 Italy Pordenone +39 (0)1678 47053 Sweden Stockholm +46 (0)8 738 7910 UK Newbury +44 (0)1635 572700 Instructions for the Installer Engineer technical data OVERALL DIMENSIONS Width: 580 mm. Depth: 510 mm. Height: 88 mm. Weight: 8 Kg. CUT OUT DIMENSIONS Width: 550 mm. Depth: 470 mm. Thickness: 30 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. IGNITION HT SPARK Spark Generator Ispra Control's BF 50046 - 230-240V 0.6 YA T120 Spark Gap : Fixed HEAT INPUT Rear Left Burner 1.9 kW (6483 BTU/HR) (semi rapid) Front Left Burner 2.9 kW Natural Gas (9895 BTU/HR) (rapid) 2.7 kW L.P.G. (9212 BTU/HR) Rear Right Burner 1.9 kW (6483 BTU/HR) (semi rapid) Front Right Burner 1.0 kW (3412 BTU/HR) (auxiliary) APPLIANCE CLASS 3 APPLIANCE CATEGORY II2H3+ GAS SUPPLY Natural gas G20 / 20mbar BURNER RAPID SEMI-RAPID AUXILIARY TYPE OF GAS (large) (medium) (small) POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 2.9 0.65 1.9 0.45 1.0 0.33NATURAL GAS 20 mbar NOMINAL FLOWVALUE = RATE m3/h 0.276 0.062 0.181 0.043 0.095 0.03137.78 MJ/m3 Ws - 50.7 MJ/ m3 NOZZLE REFERENCE 1/100 mm119 Adjust. 96 Adjust. 70 Adjust. NOMINAL THERMAL LPG GAS POWER kW 28-30/37 mbar NOMINAL FLOW VALUE = RATE g/h 49.92 MJ/Kg NOZZLE REFERENCE 1/100 mm Burner Dia. Tap By-pass 1/100 mm 2.7 0.65 1.9 0.45 1.0 0.33195 46.8 137 32.4 72 23.886 40 71 32 50 28 Tap colour Auxiliary 28 Red/Red Semi-rapid 32 Blue/Blue Rapid 40 Black/Black Aeration adjustment none Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm. between the rear edge of the hob and the wall. A minimum distance of 100 mm. must be left between the side edges of the hob and any...

Dieses Handbuch ist für folgende Modelle:
Kochfelder - GAS HOB 84602 G (130.35 kb)
Kochfelder - GAS HOB 84602 G (130.35 kb)
Kochfelder - GAS HOB 84602 G (130.35 kb)
Kochfelder - GAS HOB 85600 G (130.35 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien