Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung AEG, modell 25742 GM

Hersteller: AEG
Dateigröße: 430.55 kb
Dateiname: 6108f71c-83df-6e64-0d33-4375d7f93b42.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


-This guarantee relates to you and cannot be transferred to another user. -Your new home is within the European Community (EC) or European Free Trade Area. -The product is installed and used in accordance with our instructions and is only used domestically i.e. a normal household. -The electrical supply complies with the specification given in the rating label. -The product is installed taking into account regulations in your new country. Before you move please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0) 3 44 62 29 29 Germany Numberg +49 (0) 911 323 2600 Italy Pordenone +39 (0) 1678 47053 Sweden Stockholm +46 (0) 8 738 7910 UK Slough +44 (0) 1753 219899 MAXIMUM MINIMUM G 20 G30/G31 BURNER OUTPUT OUTPUT 20 mbar 28-30/37 mbar TYPE (gcv) kW kW Nozzle Nominal Nozzle Nominal marking flow rate marking flow rate 100/mm m3/h 100/mm g/h Small aux burner 1,00 0,30 76 0,095 50 73 Medium semi-rapid b. 1,65 0,32 94 0,157 65 120 Large rapid burner 3,00 0,65 128 0,286 85 219 T.F. burner std 4,25 1,50 63+140 0,405 37+97 310 MAXIMUM MINIMUM G 20 G30/G31 BURNER OUTPUT OUTPUT 20 mbar 28-30/37 mbar TYPE (gcv) kW kW Nozzle Nominal Nozzle Nominal marking flow rate marking flow rate 100/mm m3/h 100/mm g/h Small aux burner 1,00 0,30 76 0,095 50 73 Medium semi-rapid b. 1,65 0,32 94 0,157 65 120 Large rapid burner 3,00 0,65 128 0,286 85 219 T.F. burner std 4,25 1,50 63+140 0,405 37+97 310 Technical Data Dimensions in mm: Hob H x W x D 90 x 680 x 510 Installation opening W x D 560 x 480 Burner power in kW: Small auxiliary burner 1,00 Medium semi-rapid burner 1,65 Large rapid burner 3,0 Triple flame burner standard 4,25 Category II 2H3+ Gas intake connection G 1/2” Gas pressure G20 - 20 mbar Electricity supply 230 V ~ 50 Hz Appliance class 3 By-pass diameters Burner O Tap By-Pass 1/100 mm Small auxiliary 27 Medium semi-rapid 29 Large rapid 39 Standard 65 Instructions for the installation technician CAUTION: All responsibility for any damage deriving from installation in breach of the regulations in force or from failure to comply with the accident prevention regulations. This appliance shall be installed in accordance with the regulation in force and only in a wellventilated space .Read the instructions before installing or using this appliance.In the UK the regulation and standards are as follows: In your own interest and that of safety, it is law that all gas appliances must be installed by competent persons. CORGI registered installers undertake to work to safe and satisfactory standards.Failure to install the appliance correctly could invalidate any warranty or liability claims and leat to prosecution. The appliance must be installed in accordance with. All relevant British Standards /Codes of Pratice, in particular BS 5440 Part 2 1989 and: For Natural Gas-BS 6172 :1990 and BS 6891:1988 (current edition) The Gas Safety (installation and Use) regulations 1994 (current edition) The relevant Building / IEE regulations (current edition) Provision for ventilation The room containing the appliance should have an air supply in accordance with B.S. 5440 Part 2: 1989.All rooms require an openable window or equivalent while some rooms require a permanent vent in addition to the openable window. The appliance should not be installed in a bedsitting room with volume less than 20 m3. If it is installed in a room of volume less than 5m3 an air vent off effective area 100 cm2 is required; If it is installed in a room of volume between 5 m3 and 10 m3, an air vent of effective 50 cm2 is required: while if the volume exceeds 11 m3, no air vent is required. However, if the room has a door that opens directly to the outside, no air vent is required even when the room volume is between 5 m3 and 10 m3 . If the are other fuel burning appliances in the same room, B.S. 5440 Part 2:1989 should be consulted to determine the requisite air vent requirements Location of appliance The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm, between the rear edge of the hob and the wall. A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm. If it is fitted below 400 mm. a space of 50 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. Connection to the gas supply Ensure that the gas type at the installation site is the same as that stated on the appliance rating plate. On the end of the shaft, which includes the GJ 1/2” threaded elbow, adjustment is fixed so that the was...

Dieses Handbuch ist für folgende Modelle:
Kochfelder - 25742 GM (430.55 kb)
Kochfelder - 25742 GM (430.55 kb)
Kochfelder - 25742 GM (430.55 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien