|
Anleitung Zusammenfassung
Air Care® Filter MODELS 4D7 800, 497 800, 497 300, 447 401, 447 301 AND 427 300 Air Care® models feature a two-stage air filter which attaches to the back of the humidifier. The Air Care® filters the air as it humidifies. The first stage of the air filter is a high-efficiency, electrostatically-charged filter media which traps dust, pollen and airborne pollutants. The second stage of the Air Care® filter is an activated carbon media which absorbs odors from cooking, pets or tobacco smoke. We recommend replacing the Air Care® filter at least once a year, more often if necessary. When the white filter media is coated with a layer of dust and dirt, it is time to replace the Air Care® filter. The certified water output of your humidifier will be reduced when using the Air Care® filter Air Care® filters are optional and are not required for normal operation of the humidifier. Care and Maintenance IMPORTANT: We recommend cleaning your humidifier every two weeks. Follow instructions. Humidifiers provide comfort by adding moisture to dry, heated indoor air. Toget the most benefit from the humidifier and avoid product misuse, follow allinstructions carefully, specifically the operation, care and maintenance guidelines. Please note this is an electrical appliance and requires careful attentionwhen in use. In addition, if you do not follow the recommended care and maintenanceguidelines, microorganisms may be able to grow in the water within the humidifier's reservoir. ..! CAUTION: Disconnect power before cleaning or servicing unit. ..! WARNING: It is very important that cleaning solutions, such as bleach, bacteria treatment, or descaler which could be used to clean the cabinet are not sprayed or applied to the chassis/power pak assembly. Additionally, do not immerse the power pak in water or any other solution. These solutions can cause a serious electrical malfunction of the humidifier. 1) Turn unit off by turning humidistat completely counterclockwise. For digital unit, hold speed button down for two seconds. 2) Unplug electrical cord from wall outlet. 3) Unplug interlock plug from chassis/ power pak receptacle. 4) Lift off end covers and remove both water bottles. NOTICE: Water bottles must be removed before chassis/power pak to prevent possible switch lever damage. 5) Lift chassis/power pak unit from cabinet. REMOVING SCALE 6) Carefully lift wick from cabinet, allowing any water to drain from it into water channel. Place in sink or tray to finish draining. 7) Remove any remaining water in channel with a sponge. Fill water channel with one 8 oz. cup of undiluted white vinegar. Let solution stay 20 minutes. Remove with a sponge. Clean all interior surfaces with soft brush. Dampen soft cloth with undiluted white vinegar and wipe out water channel to remove scale. 8) Rinse water channel thoroughly with fresh water to remove scale and cleaning solution before disinfecting. DISINFECTING RESERVOIR 9) Fill water channel with mixture of one teaspoon chlorine ble...
Dieses Handbuch ist für folgende Modelle:Luftbefeuchter - 447 301 (321.06 kb)
Luftbefeuchter - 427 300 (321.06 kb)
Luftbefeuchter - 447 401 (321.06 kb)
Luftbefeuchter - 496 800 (321.06 kb)