Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Essick Air, modell 427 300

Hersteller: Essick Air
Dateigröße: 321.06 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


In hard water areas, more frequent replacement may be necessary to maintain your humidifier's efficiency. NOTICE: We recommend using Bemis by Essick Air Bacteria Treatment, whenever you refill the water bottles to eliminate bacteria growth. Follow the directions to determine the proper amount to be added to the 2.75 gallon water bottles. The evaporative wick does not require the use of chelating agent type water treat ments that are intended for use in Rotobelt or Water Wheel type humidifiers. Your humidifier is equipped with two water bottles. When both bottles have emptied, the humidifier fan will automatically shut off and the "Refill Water Bottles" message will light. The unit will start again automatically when the water bottles are refilled. The right bottle will empty first. If it does not do so, the humidifier may not be level. Dry air is drawn into the humidifier through the back and moisturized as it passes through the evaporative wick. It is then fanned out into the room. 1. Water bottles 2. Chassis/Power pak (motor and fan assembly) 3. Evaporative wick 4. Water channel/tray 5. Dry room air intake 6. Moist air output Locate your humidifier on an inside wall, near an electrical outlet. The humidifier should be at least 4" away from the wall for best results. Do not position the unit directly in front of a hot air duct or radiator. Assembly and Operation 1) Unpack humidifier from carton. 2) Remove all packaging materials. Check to see that you have all of the following items before discarding packaging: Fill hose Cord Set Evaporative wick Two end covers Two water bottles with caps Caster kit Air Care filter if unit is an Air Care model NOTICE: The wick and Air Care filter are packaged to prevent breakage in shipping. They must be removed from the unit and correctly installed according to these instructions prior to operation to prevent damage to the unit. CASTERS 3) Remove the water bottles, chassis and evaporative wick from the base of the humidifier. Turn the base of the empty humidifier upside down. Insert the caster stem into the large caster holes in the four corners of the humidifier bottom. The casters should fit snugly and be inserted as far as possible. Do not force. When all four casters are in place, turn the unit right side up. EVAPORATIVE WICK 4) The wick has a mounting rib on the top edge which hooks over a rib at the inside back of the cabinet. This allows the wick to hang in the water channel (see illustration). Hang evaporative wick into cabinet as shown. AIR CLEANING FILTER (Models 4D7 800, 497 800, 497 300, 447 401, 447 301 & 427 300) 5) The Air Care filter has four tangs that engage into four keyhole slots that mount the Air Care filter onto the outside of the back of the cabinet. CHASSIS/POWER PAK 6) Place the chassis/power pak unit into the cabinet ensuring that chassis/power pak seats correctly onto the front and back edges of the cabinet. BOTTLES 7) Fill the bottles with cool, fresh, preferably unsoftened water. I...

Dieses Handbuch ist für folgende Modelle:
Luftbefeuchter - 447 301 (321.06 kb)
Luftbefeuchter - 447 401 (321.06 kb)
Luftbefeuchter - 496 800 (321.06 kb)
Luftbefeuchter - 497 300 (321.06 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien