Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Aprilaire, modell & 700

Hersteller: Aprilaire
Dateigröße: 224.18 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


5. Remove the black plastic distribution tray (5) from the evaporative assembly by unsnapping the white plastic holding strips from the tabs at the end of the tray. Lightly scrape out any calcium deposits and clean the “V” notches (6), but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. See page 2 if removed. 6. Slide the Water Panel evaporator (7) out from the white plastic Scale Control Insert (8). Clean the Scale Control Insert by twisting and flexing it to loosen the calcium deposits, or use a putty knife. Inspect the Water Panel evaporator (Stock No. 10 for Model 558 and Stock No. 35 for Model 568) and replace with a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel back into the Scale Control Insert with the black colored spot up and snap the black distributor tray back into place. 7. Re-install the Water Panel evaporative assembly into the unit by fitting its drain tube into the round receptacle at the base of the unit. Push the assembly in at the top against the beveled tabs that will hold it in place. Push the end of the feed tube back firmly into the nozzle and replace the front cover. 8. Remove the drain hose (9) from the bottom of the unit and bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the black drain fitting. 9. Turn on water supply. 10. Check system operation: Humidifier Control: Automatic Check system operation by setting the knob to “Test.” With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. 11. Set Humidifier Control to its original position. - 12 S for APRILAIRE HUMIDIFIER MODEL 600 CAUTION! Sudden operation may cause personal injury or property damage. Turn humidistat or control to “off” or lowest setting before servicing. 1. Front Cover 2. Feed Tube 3. Nozzle 4. Water Panel Evaporative Assembly 5. Distribution Tray 6. “V” Notches 7. Water Panel 8. Scale Control Insert 9. Drain Hose 10. Integral Damper 1. Note humidistat or control setting and turn dial to the “OFF” position. 2. Turn off water supply. 3. Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base with both hands. Set aside. 4. Carefully pull the plastic feed tube (2) out of the nozzle (3) at the top of the Water Panel evaporative assembly (4). Pull this assembly out by grasping at top and tipping out. 5. Remove the black distribution tray (5) from the evaporative assembly by lifting straight up from the scale control insert (8). Lightly scrape out any calcium deposits and clean the “V” notches (6) but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. See page 2 if removed. 6. Slide the Water Panel evaporator (7) out from the white plastic Scale Control Insert (8). Clean the insert frame of calcium deposits with a putty knife. Inspect Water Panel evaporator (Stock No. 35 for Model 600) and substitute a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel back into the scale control insert with the black colored spot up and snap the black distribution tray back into place. 7. Re-install the Water Panel evaporative assembly into the unit by fitting its drain tube into the round receptacle at the base of the unit. Push the assembly in at the top against the beveled tabs that will hold it in place. Push the end of the feed tube back firmly into the nozzle and replace the front cover. 8. Remove the drain hose (9) from the bottom of the unit and bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the drain fitting. 9. Turn on the water supply. 10. Check system operation: Humidifier Control: (Automatic or Manual) Check system operation by setting the knob to “Test.” With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE. 11. Set Humidifier Control to its original position. MODEL - 13 MODEL 700 MODEL 700 S for APRILAIRE HUMIDIFIER MODEL 700 WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing. 4 5 6 7 8 9 1 23 1. Front Cover 2. Base 3. Water Panel 4. Distribution Tray 5. ”V” Notches 6. Water Panel 7. Scale Control Insert 8. Drain Hose 9. Power Cord 1. Note humidistat or control setting and turn dial to the “OFF” position. 2. Disconnect electrical power and turn off water supply. 3. Unlatch humidifier cover assembly (1) from base assembly (2) at the bottom of the cover, lift, and set aside. 4. Pull out the evaporative assembly (3) by grasping at the top and tipping out. 5. Remove the black distribution tray (4) from the evaporative assembly (3) by unsnapping the white plastic holding strips from the tabs at the end of the tray. Lightly ...

Dieses Handbuch ist für folgende Modelle:
Luftbefeuchter - 568 (224.18 kb)
Luftbefeuchter - 558 (224.18 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien