FROST CONTROL APPLICATION/OPERATION When outdoor air temperatures are extremely cold, moisture condensation and frosting on the energy recovery wheel is possible. Frost control is an optional feature that will prevent wheel frosting. Two options are available: 1) Timed Exhaust frost control and 2) Preheat frost control Timed exhaust frost control includes a thermostat (with probe) mounted in the supply air inlet compartment (see FIGURE 13, page 14) and a timer (Figure 12) mounted in the HRE control center. The thermostat will turn on the timed exhaust frost control feature at a predetermined field adjustable outdoor air temperature (referred to as the Frost TABLE 1 Threshold temperature). The typical temperature setting corresponds to the indoor air relative humidity as shown in TABLE 1. Testing (refer to FIGURE 12) • Set the Timer Scale for T1 and T2 to 1 minute. Set the Timer Settings for T1 and T2 to 1.0. Set the dip Indoor RH @ 70°F Frost Threshold Temp 20% 2°F 25% 7°F 30% 14°F switch to the down position. •Turn the temperature sensor up as high as possible. The supply blower should cycle on for one minute, then turn off for one minute. Dip Switch •After testing, set the Timer Scale as follows: T1 = 10 minutes, T2 = 1 hour T2 • Set the Timer Settings as follows: T1 = 0.5, T2 = Timer A1 B1 1516 18 A20.20 0.41.0 0.60.8 0.20 0.41.0 0.60.8 T21 MIN T11 MIN Scale 0.5. The timer is now set for 5 minutes off and 30 minutes on. Preheat frost control (see FIGURE 11, page 12) includes a thermostat (with probe) and an electric heater located in the T1 supply air inlet compartment and an air pressure switch in the supply air outlet compartment. The thermostat should be set according to the Frost Threshold temperatures shown in TABLE 1. FIGURE 12 When the outdoor air temperature reaches the thermostat setting, the electric preheater will turn on and warm the air entering the energy wheel. Testing •Turn the thermostat as high as it will go. The heater should turn on. • If it doesn’t, either put the supply side doors on or temporarily jumper the air pressure switch to avoid nuisance tripping of the pressure switch. Remember to remove the jumper. DIRTY FILTER SWITCH SETUP This unit may be equipped with a dirty filter switch that functions on differential air pressures to close a relay when the unit filters are clogged and need cleaning. This switch has not been set at the factory due to external system losses that will affect the switch. This switch will need minor field adjustments after the unit has been installed with all ductwork complete. The dirty filter switch is mounted in the exhaust inlet compartment next to the electrical control center. To adjust the switch the unit must be running with all of the access doors in place, except for the compartment where the switch is located (exhaust inlet compartment). Remove the switch cover plate. The adjusting screw is located on the top of the switch. Open the filter compartment and place a sheet of plastic or cardboard over 50% of the filter media. Replace the filter compartment door. Check to see if there is power at the alert signal leads (refer to electrical diagram). If there is no power, turn the adjustment screw on the dirty filter gage clockwise until you have power. Open the filter compartment and remove the obstructing material. Replace the door and check to make sure that you do not have power at the alert signal leads. The unit is now ready for operation. ECONOMIZER APPLICATION/OPERATION The energy recovery wheel may be de-energized for the purpose of providing economizer (free cooling) operation. This can be achieved with a signal from a Temperature or Enthalpy sensor mounted in the supply air inlet compartment (see FIGURE 13). This Primary sensor will de-energize the energy wheel when the outdoor air temperature (factory default is 65°F) or enthalpy (factory default is the ‘D’ setting) is below the field adjustable set point. An additional Override temperature sensor is also furnished in the supply air inlet compartment to deactivate economizer mode (see FIGURE 13). The Override (with field adjustable set point) is set at some temperature lower than the Primary sensor (factory default is 50°F). Effectively, the two sensors create a deadband where the energy recovery wheel will not operate and free cooling from outside can be brought into the building unconditioned. Testing (terminals referenced below are in the unit control center — see FIGURE 5, Item #7) Temperature sensor with Override •Turn both Temperature and Override thermostats down as low as they go. The wheel should be rotating. •Turn the Temperature sensor up as high as it goes, and keep the Override sensor as low as it will go. The wheel should stop rotating. •Turn both sensors as high as they will go. The wheel should start rotating. • Set the Temperature sensor to the desired temperature for economizer operation to begin. Set the Override sensor to the desired temperature for economizer operati...
Dieses Handbuch ist für folgende Modelle:Luftbefeuchter - HRE-20 (358.34 kb)
Luftbefeuchter - HRE-55 (358.34 kb)
Luftbefeuchter - HRE-45 (358.34 kb)