Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Air-O-Swiss, modell AOS2055A

Hersteller: Air-O-Swiss
Dateigröße: 3.91 mb
Dateiname: AOS_2055A_ManualUSA10_EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The individual dust particles are ionized (charged) and stick to the humidifier discs. Special humidifying discs rotate in a water bath inside the unit; this cleanses the air passing over them of impurities in a natural way – in the same way that air is washed by the rain in nature. The air humidification takes place according to the selfregulating principle of cold evaporation. The appliance therefore generates ideal air humidity, without the need for additional control units. A specially tuned antimicrobial protection system (Ionic Silver Stick®) prevents the formation of microbes in the water of the base unit. No chemical additives are required to keep the water clean. Unpacking • Remove the appliance carefully from the packaging (10 – 12). Place your hands underneath the product to pull it out of the box. The top part of the unit is only placed on the base; it is NOT attached. • Remove the plastic bag from the unit (13). • Remove all cardboard pieces from the disc pack (14). • Check the details of the electrical supply on the rating plate (15). • Use the original packaging to store the appliance if you do not use it throughout the year. 10 11 12 8 9 en Fragrance container and rotary lock opener for humidifying discs Water base Control panel Air outlet Cover Rotary lock Description of the appliance 1 disc pack with 16 humidifying discs Water tank Water tank cap Ionic Silver Stick® (ISS) Air inlet 13 14 15 Putting into operation The best location for your appliance is: • On the floor, or on a level, dry surface in the room. • Pay proper attention to easy accessibility and sufficient space for servicing and cleaning the unit. • Read the section «Filling the tank» on how to fill the water tank (16 – 20). • Place the water tank on the lower part (20). • Connect the power cable to the outlet and switch the appliance on using the On/Off switch. • The unit will reach full humidity output about 10 – 15 minutes after you switch it on. • Ensure that the cable is not trapped (9). Do not switch on the unit if the cable is defective (2). 10 en Filling the tank Always unplug the unit before removing the water tank. Do not operate the appliance when the water tank is empty! Only fill the water tank with fresh, cold tap water. Use water additives at your own risk. We do no accept any liability for possible reductions in performance or damage. Do not put the water tank under pressure, e.g. by filling with carbonated mineral water. Do not add any essential oils or fragrances to the water; the plastic material might become discolored and damaged. Close cap tightly (19) to prevent water from leaking out of the tank. • Remove the water tank (16). • Ensure that there are no foreign objects in the water tank. • Remove the water tank cap from the tank (17). Fill the tank with fresh, cold tap water (18). Fully close the water tank cap to prevent the water tank from leaking (19). Place the water tank on the water base (20). • After filling the water tank, most of the water will empty into the base. The water tank may be filled a second time (base will not overflow). • Connect the cable to the outlet and switch the appliance on. • The red empty indicator light may stay illuminated for some seconds until the base is filled with water. The unit is fitted with an automatic cut-off switch. As soon as the water tank is empty, the unit switches off automatically; the empty indicator illuminates (also see section «Operating 2055A»). Use of fragrances The base contains a special fragrance container (21). A cotton ball soaked with fragrance can be placed in this container. Place fragrances only in the container provided! Do not pour fragrances in fragrance container directly! Use with cotton ball only. Water additives (e.g. essential oils, fragrances, water conditioners) must NOT be used in the tank or anywhere else in the appliance! Even a small amount can damage the plastic or cause cracks. The material is not suitable for the use of additives. One drop is enough to damage the water tank and therefore render the unit unusable. Appliances that are damaged by additives are excluded from the warranty. The fragrance container is also used as a tool for opening the rotary locks of the humidifying discs. To learn more about removing the discs, refer to section «Cleaning the humidifying discs». 19 16 17 18 20 21 Operating 2055A AEBCD A) Rotary switch Connect the appliance to an outlet and turn rotary switch A from position B (off) to position C or D as required. Position D is especially quiet (night mode). Position C (normal mode) achieves maximum humidity output. The disc rotation speed remains constant with both mode selections. The fan rotation speed increases with level II (C). B) Switching on/off If the rotary switch is in position B, the appliance is switched off. C) Normal mode If you select position C, then normal mode is set, and the appliance reaches maximum humidity output. D) Night mode If you turn the rotary switch to position D, t...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien