Closed defect summary
Solution
When an M-EOS-based switch is used as a seed switch and is attached
Fixed in DCFM 10.3.0
nl
to an FOS-based switch, the connected end devices are not accurately
Workaround prior to this version:
displayed in the Topology. The device attached to the FOS-based
nl
Use the FOS-based switch as the seed
switch is shown without any connection, and the device attached to
switch.
the M-EOS-based switch is not shown at all.
Fixed in DCFM 10.3.0
nl
M-EOS Element Manager cannot be launched after editing the SNMP
Workaround prior to this version:
values from the Discovery Setup dialog.
nl
Delete and then rediscover the fabric.
The FCIP tunnel between two HP StorageWorks 400 MP Routers does
Fixed in DCFM 10.3.0
not appear in the Topology.
When monitoring performance, the I/O flow does not appear for some
Fixed in DCFM 10.3.0
switches or for GbE ports with one FCIP tunnel.
The Connected Device Property information is not updated when a
CNA connected to HP StorageWorks 2408 FCoE Converged Network
Fixed in DCFM 10.3.0
Switch is down in the Virtual FCoE Ports tab. The Connected Device
Property value displays 1 instead of 0.
Unable to download firmware using an external FTP as external FTP
server, and SCP server options are not available in the Firmware
Fixed in DCFM 10.3.0
Management dialog if an external FTP server is selected.
If the HP StorageWorks 2408 FCoE Converged Network Switch is
Fixed in DCFM 10.3.0
selected from the Connectivity Map, the Product Tree toggles or flickers.
You cannot activate zone config while bad zone config is dis-
Fixed in DCFM 10.3.0
played.
During historical data collection, event logs can grow to several GBs
Fixed in DCFM 10.3.0
in size and fill the hard drive.
When IFLs are removed from back-to-edge routing, the Topology occa-
sionally appears blank and causes a NULL pointer exception in the
Fixed in DCFM 10.3.0
Client log.
Access Gateway-based logins are displayed incorrectly in DCFM.
Fixed in DCFM 10.3.0
The right-click menu of unoccupied ports in M-EOS-based switches lists
Fixed in DCFM 10.3.0
CGWL options instead of the correct options.
The local client displays the Master Log correctly, but remote clients
Fixed in DCFM 10.3.0
display a blank Master Log.
HP StorageWorks Edge Switch 2/12 running firmware 9.9.x is missing
from the Topology after migration from EFCM to DCFM; it must be
Fixed in DCFM 10.3.0
rediscovered to appear.
The Port Picker dialog shows an incorrect port count when switches
without an EGM license are selected.
nl
Fixed in DCFM 10.3.0
NOTE:
nl
All HP switches have this license by default.
Discovery status is inconsistent for VF switches in the fabric when a
Fixed in DCFM 10.3.0
non-VF switch is discovered as the seed switch.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional
29


...

Dieses Handbuch ist für folgende Modelle:
Media Storage - HP StorageWorks Director 2/64 base 32 port config (464.62 kb)
Media Storage - HP StorageWorks Director 2/140 (464.62 kb)
Media Storage - HP StorageWorks Edge Switch 2/12 (464.62 kb)
Media Storage - HP StorageWorks Edge Switch 2/32 (464.62 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien