Hersteller: HP
Dateigröße: 324.74 kb
Dateiname:
|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
Table 7 HP Network Advisor 11.1.0 closed defects
Closed fixes summary
Solution
Brocade Access Gateway (AG) switches running Fabric OS 5.3 were not
Fixed in HP Network Advisor 11.1.0.
shown in DCFM and an inappropriate message was shown when trying to
rediscover the fabric.
Master log reports port number and port index as one greater than actual
Fixed in HP Network Advisor 11.1.0.
value.
DCFM server runs out of memory when managing HP StorageWorks SAN
Fixed in HP Network Advisor 11.1.0.
Director 2/128 or HP StorageWorks 4/256 SAN Director switches for
several weeks.
Server backup fails to authenticate with Network drive after a server reboot. Fixed in HP Network Advisor 11.1.0.
The twelfth character of a LUN Serial Number (LSN) is getting dropped on Fixed in HP Network Advisor 11.1.0.
some paths in the Encryption Disk LUN View.
Master Trunk ports in product tree and connections between AG and a
Fixed in HP Network Advisor 11.1.0.
switch are not shown properly when F_Port trunking is enabled on the AG
setup.
Remote VE_Port WWN is shown as missing and with a red icon under end Fixed in HP Network Advisor 11.1.0.
devices.
Fault Management – “VFID” is shown as “Chassis” for “Switch name change Fixed in HP Network Advisor 11.1.0.
event” in the master log.
There are yellow dotted lines shown between the segmented switch and
Fixed in HP Network Advisor 11.1.0.
the End Device in the re-discovered fabric.
In the Client, IFL/ISL connections are not being displayed correctly in the
Fixed in HP Network Advisor 11.1.0.
topology view when multiple circuits are added with different GigE ports
for a tunnel.
For zoning, sorting of ports is not accurate in the Hex display mode for the Fixed in HP Network Advisor 11.1.0.
user port number.
In the Client, the latest topology changes are not reflected; the yellow dotted Fixed in HP Network Advisor 11.1.0.
line is not shown when the tunnel is deleted.
In the Device Tree, on selecting an E_Port on switch1, after 1 minute focus
Fixed in HP Network Advisor 11.1.0.
changes to the same port under switch-2, and is misleading to the user.
When a user attempts to delete a logical switch the operation may fail with Fixed in HP Network Advisor 11.1.0.
the error message internal server error.
A user is unable to edit the commit rate of a second circuit after the first
Workaround prior to upgrade: Close and
circuit has been modified without closing and reopening the FCIP Tunnel
reopen the circuit dialog on different
dialog box.
circuits to perform the edit operation.
Fixed in HP Network Advisor 11.1.0.
In the Client, the Logical Switch Sequence Number is displayed incorrectly Fixed in HP Network Advisor 11.1.0.
in the Switch Properties Dialog.
In Port Fencing, Switch-level Alert was missing when a port is fenced for
Fixed in HP Network Advisor 11.1.0.
Link reset violation type.
FCIP Circuits do not come up and stay in an 'In progress' state after
Workaround prior to upgrade: Change
changing the commit rate.
commit rates on both the local and remote
ends separately through the CLI if there
are different VLAN tags at both ends.
Fixed in HP Network Advisor 11.1.0.
At times hosts are not displayed and a user will not be able to view the
Workaround prior to upgrade: Hit the
LUNs configured for a container.
refresh button in the target dialog to see
the hosts configured.
Fixed in HP Network Advisor 11.1.0.
18
...Dieses Handbuch ist für folgende Modelle:
Media Storage - HP 4400 Dual Controller Enterprise Virtual Array (324.74 kb)
Media Storage - HP StorageWorks EVA4400 Dual Controller Array (324.74 kb)
Media Storage - HP StorageWorks EVA4400 Dual Controller w/(8) 8Gb SFP/(2) 8Gb Embedded Switch (324.74 kb)
Media Storage - HP StorageWorks EVA4400 Dual Controller w/Embedded Switch (324.74 kb)