Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung HP, modell HP 4400 Dual Controller Enterprise Virtual Array w/Embedded Switch

Hersteller: HP
Dateigröße: 177.87 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung





Figure 2 Removing a management module
Verifying component failure
Use the following methods to verify component failure:

Verify the management module status using HP
P6000 Command View:
1.
In the navigation pane, select Storage
System→Hardware→Controller
Enclosure→Management Module.
2.
In the Management Module Properties
window, observe the status. An operational
state of
(Failed) indicates a fault that may
require a replacement.
3.
To help identify the correct enclosure, select
Controller Enclosure in the navigation pane,
and then click Locate→Locate On in the
content pane.
Installing a management module
This causes the blue UID indicator to blink
1.
Insert the management module partially into the
on the controller enclosure.
slot in the controller enclosure.

Observe the array management module LEDs:
2.
Lift up the latch (1, Figure 2 (page 2)) and push
the module forward until you hear a click. This
◦ Green—Normal operation
indicates that the module is fully seated.

3.
Plug the Ethernet cable into the module.
Amber—Fault condition (except during start
up, when some cycling of the LED occurs)
NOTE:
Due to hardware restrictions, some
◦ Off—No active remote management
older HP P6000 Command View Versions do
not work with current management modules. In
◦ Ethernet LEDs—Solid green indicates a link.
this case, when you attempt to code load an
Flashing yellow indicates activity.
older .pkg file, the load fails with a P6000
Control Panel message indicating the .pkg is
incompatible with the hardware.
Removing a management module
Observe proper antistatic guidelines when working
on computer hardware.
Verifying proper operation
After replacing the management module, do the
NOTE:
To maintain configuration information,
following to verify the component is operating
such as IP address, perform this procedure with
properly:
power on.
NOTE:
Wait approximately five minutes for
1.
Unplug the Ethernet cable from the module.
the system to check the component status.
2.
Lift up the latch on the module (1, Figure 2 (page
2))
and pull the module out slightly.

Verify that the green LED is lit. If it is not, try
3.
Position one hand under the module, and with
reseating the management module.
the other hand, pull the module out of the

From HP P6000 Command View, navigate to the
controller enclosure (2, Figure 2 (page 2)).
component as described in “Verifying component
failure” (page 2), and verify that the status is
(Good).
NOTE:
You cannot store modifications to the
management module settings if the array is not
initialized.
Page 2


...

Dieses Handbuch ist für folgende Modelle:
Media Storage - HP 4400 Dual Controller Enterprise Virtual Array (177.87 kb)
Media Storage - HP EVA P6350 450GB 10K SAS Field Starter Kit (177.87 kb)
Media Storage - HP EVA P6350 450GB 10K SAS FIO Starter Kit (177.87 kb)
Media Storage - HP EVA P6350 900GB 10K SAS Field Starter Kit (177.87 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien