Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Welch Allyn Medical Diagnostic Equipment, modell SCANTEAM 5770

Hersteller: Welch Allyn Medical Diagnostic Equipment
Dateigröße: 315.14 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Worldwide Charging Information The battery pack is rated for 110/120 50/60 Hz applications but may be recharged worldwide using a step down transformer. The step down transformer, provided with each Cordless Scanner shipped outside North America, changes typical 240V AC into 120V AC output. All batteries shipped outside North America are fused to protect against charging at any higher voltage than 120V AC. Contact your distributor for more information or to order additional step down transformers. Battery Pack Recommendations • NiCad batteries are shipped uncharged and need to be fullycharged and discharged two or more times to be fully conditioned. • Charge the battery for 24 hours the first two or more times to fully charge the battery. • Charge the battery pack immediately before use or at least within a couple of days of use. • Remove the battery pack from the power outlet after charging is completed. Avoid extended overcharging; do not leave the battery charging for more than two days. • Periodically fully discharge the battery pack. • Avoid using the battery pack in extreme temperatures. • Do not disassemble the battery pack. There are no user-serviceable parts in the battery pack. Proper Disposal of the Battery Pack When the battery pack has reached the end of its useful life, the batteries should be disposed of by a qualified recycler or hazardous materials handler. Do not incinerate the battery pack or dispose of the battery pack with general waste materials. Contact the Product Service Department (see page 5) for recycling or disposal information. Cordless Quick Start Guide Cordless Quick Start Guide 3 Note: It is important that you charge a NiCad battery for 48 hours prior to first use. No damage occurs if this is not done, but the battery capacity will not be at 100%. A NiMH battery requires charging for only 24.5 hours. Recharge Time (NiCad or NiMH): 8 hours at 120 VAC, 50/60 hz Cordless Scanner Charge the Battery Pack by following the steps shown below: Rechargeable Battery Pack E The LED on the bottom of the battery pack will light red when the unit is charging; it shows green when it is fully charged and ready to use. I After battery pack is fully charged, attach to the Cordless Scanner by pressing the pack firmly (align the prongs on the pack with the mating receptacles) in the base of the scanner until the release buttons click, holding the pack firmly in place. (When you attach a charged battery pack to the Cordless Scanner, you will hear a single beep.) I If you haven’t set up your Cordless System, refer to the “Setting Up and Connecting the Cordless System” section in the System Manual for instructions. Charging Your Battery Pack Plug the battery pack into a wall socket in North America only. Failure to comply could result in equipment failure. When the battery pack needs recharging, the yellow LED on top of the scanner pulses in short, continuous blinks and the scanner won’t beep when you pull the trigger. If the LED stops flashing when the temperature lowers or you do not use the battery pack for some time, you still need to charge the battery pack to avoid damaging the battery pack or causing scanner memory loss. Battery Pack Clip (2 Places) E Fully charge the battery (see page 2). Plug the battery pack directly into any common 120 Volt AC outlet in North America. If outside North America, use the step down transformer provided with the scanner. 4 Cordless Quick Start Guide Associating the Cordless Scanner to a Base Important: Make sure the Cordless Scanner’s battery pack has been fully charged. See page 3 for charging instructions. Using the Cordless Scanner, scan the Association Bar Code (the bar code label on the top of the Base) to link that scanner to the Base (see the illustration below). Two quick beeps followed by clicking, then a single beep indicates a “good” association. The scanner is in communication with the Base. Cordless CCD or Laser Scanner Cordless Base Association Bar Code Note: To set up and connect the Cordless System to the host system, refer to the Cordless System Manual that is shipped with each Base unit. The System Manual includes all programming selections, more detailed explanations of the Cordless System, product specifications, scan maps, connector illustrations and pinouts, maintenance and troubleshooting information. After association, if the battery pack is removed from the scanner and replaced, the scanner automatically re-associates to the base if the base has remained powered up. In this case, the scanner beeps when a charged battery pack is installed, then clicks and beeps a second time after full association, about five to ten seconds later. Limited Warranty Welch Allyn, Inc., hereby warrants its products to be functional and free from manufacturing defects at the time of delivery. Welch Allyn, Inc. further warrants that it will replace or repair, at its option, any unit that fails to perform according to Welch Allyn’s published specifications d...

Dieses Handbuch ist für folgende Modelle:
Ladenausstattung & -werbung - SCANTEAM 3470 (315.14 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien