|
Anleitung Zusammenfassung
The timer cycle 12 counter will be increased by one and updated on the display. Under CS operation mode, the timer, after counting down to 0:00'00", will stay at 0:00'00"0 until you press [RESET] to reload the timer value. Under CU operation mode, the timer, after counting down to 0:00'00"0, will count up and stop at 19:59'59"9. How to set the timer Press and hold [RECALL] for 2 seconds to activate timer setting. Timer setting starts with second digits, which are shown blinking. You can press [START] to advance the flashing digits. Or you can press [RESET] to select other digits. The setting is in sequence of second, minute, hour and timer operating mode (CR, CS and CU). NOTE: You can only set Hour, Minute and Seconds. The 1/10 second cannot be set. Press and hold [RECALL] for 2 seconds. Timer setting starts with second digits. Press [RESET] to move to minute digits. Press [RESET] further to go to hour digits. Hour digits can be adjusted from 0 to 19. {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 58' 55 {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 58' 57 {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 59' 02 Press [RESET] again to adjust the operating mode. Press [START] to switch the operating modes among CR, CS and CU. {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 59' 11 At the end of setting, press [RECALL] or [MODE] to leave setting mode. Pacer Mode Press [MODE] until you enter the Pacer mode. In the Pacer mode, you can set the standard pacer speed from 5 to 240 beats per minute in the following values: 5, 10, 20, 30, 40, 50, 60, 80, 100, 120, 150, 180, 200, 240 In Pacer mode, the display will be: PACER P -5 The digits are flashing to indicate that the pace count is ready for setting. Press [RESET] to select the pace count. Once the desired pace count is selected, press [START] to confirm the setting and start the pace count.The display will show the elapsed time on the upper line, the pace count number on the middle and the pace count value on the lower display. 0: 00' 51" 85 C - 00 51 P -60 Press [STOP] to stop the pace count. The "STOP" indicator is ON to show the status and the display freezes. To restart the pace count, press [START] again. Or press [RESET] to reset the time elapsed and the pace count number as follows: 0: 00' 00" 00 C - 00 00 P -60 Stroke Measurement Press [MODE] until you enter the Stroke Measurement mode. The display will be as follows. STROkE 0. 0 In the Stroke Measurement mode, the duration of 3 strokes is taken and the stroke frequency (counts per minute) is calculated. As the stroke frequency falls out of the range of 10 - 180, "Err" will appear to show the error condition. Press [START] to start the measurement. During the 1st second, 180.0 will be shown and flashing as below. STROkE 180. 0 At the end of the first second, the display will become steady. If measurement is stopped in the first second (stroke frequency > 180), error signal " Err " will be shown. After the first second has elapsed, the instantaneous measurement reading will be shown.When you press [STOP], the display will show the steady stroke measurement reading. If the measurement lasts for more than 18 seconds (stroke frequency < 10), an error signal "Err" will be displayed. When the measurement is stopped, press [RESET] to reset the displayed reading to "0.0". Speed Mode (AE760M100 & AE790M500 Model only) Press [MODE] until you enter the Speed mode. The display will be as follows. DIST KM {000} 0. 0 0 0 0: 00' 00" 00 LAP STOP 0: 00' 00" 00 (Note that the default setting is KM. Hence "KM" icon will be ON.) The upper line shows the distance or speed. The lap time is in the middle line, while the total time is displayed on the lower line. In the Speed mode, you can record a number of lap times and speeds for covering the distance you program into the chronograph.. Before starting to use the Speed mode, you need to enter the distance as explained below. Otherwise, the speed measurement won't work. Distance Setting Press [RECALL] for 2 seconds to enter setting mode, the unit icon flashes. DIST KM {000} 0 0 0. 0 0 0 0: 00' 00" 00 LAP STOP 0: 00' 00" 00 Press [START] to toggle between KM and MILE. To select the following digits, press [RESET]. The far right digit will blink and you can set the distance from the least significant digit to the most significant digit. The distance can be set in the range 0.000 to 1999.999 km (or ML). Press [RECALL] OR [MODE] to exit from the setting mode. As an example, the distance is set at 400m. DIST KM {000} 0. 4 0 0 0: 00' 00" 00 LAP STOP 0: 00' 00" 00 Speed Mode Running Press [START] to start the Speed timer. The "STOP" indicator is OFF. The maximum time can be up to 19 hr. 59 min. 59.99 sec. DIST KM {000} 0. 0 0 0 0: 00' 00" 00 LAP RUN 0: 00' 05" 35 While the timer is running, press [LAP/SPLIT] to record the lap time and the corresponding speed (in km/hr or mph) will be displayed on the upper line.The lap counter (shown on the upper left corner) will advance by one. DIST KM {001} 2 5. 7 6 0 0...
Dieses Handbuch ist für folgende Modelle:Herzfrequenzmesser - 760M (479.79 kb)
Herzfrequenzmesser - 790M (479.79 kb)