Login:
Stimmen - 5, Durchschnittliche Bewertung: 3.4 ( )

Anleitung Lumiscope, modell 1133

Hersteller: Lumiscope
Dateigröße: 497.12 kb
Dateiname: ProductAdditionalInfoItemOriginal2716.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The device, accessories and packing must be disposed of as waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal. C€ 0123 CE marking in conformity with EC directive 93/42/EEC A Attention, consult accompanying documents ft Type B Applied Part 4 3 GENERAL Intended use This instruction manual is intended to assist the user in safe and efficient operation of the Upper Arm Automatic Digital Blood Pressure Monitor Model 1133 (hereinafter: device). The device must be used in accordance with the procedures described in this manual. It is important to read and understand the entire manual, especially the section. This device is intended for the noninvasive measurement of systolic and diastolic arterial blood pressure and pulse rate in adults (age 15 and above). Consult your physician before using this device on children or persons with arrhythmia. Principle of Operation This device uses oscillometric technology with Fuzzy Algorithm to measure the arterial blood pressure and pulse rate. The cuff is wrapped around the upper arm and inflated automatically. The sensor of the device catches weak fluctuation of the pressure in the cuff produced by extension and contraction of the artery of the arm in response to each heartbeat. The amplitude of the pressure waves is measured, converted in millimeters of the mercury column, and is displayed by digital value. Note: This device cannot provide reasonable accuracy if used or stored at temperature or humidity beyond the range stated in the section of this manual. 5 4 TIPS ON TAKING BLOOD PRESSuRE MEASuREMENT 1. It is necessary to know that arterial blood pressure is subjected to sharp fluctuations. The level of the arterial blood pressure depends on many factors. Generally arterial blood pressure is lower in the summer and higher in the winter. Arterial blood pressure changes with atmospheric pressure and is affected considerably by many factors, e.g. physical loads, emotional excitability, stress, meals, etc. Medicines, drinking, and smoking can affect blood pressure. When blood pressure is measured in the hospital, the value is sometimes higher than when taken at home. This is believed to be associated with anxiety experienced during the hospital/clinic visit. Blood pressure may be elevated when taken in low temperatures. If this device was stored at a low temperature, it is necessary to leave it at room temperature for at least 1 hour, otherwise the measurement can be inaccurate. Blood pressure varies by age and from person to person, and it is recommended to record blood pressure daily; then you can check with your physician to find out what normal blood pressure is for you. The illustration above is from The British Hypertension Society 2. Patients with cardiovascular diseases: Take measurement under doctor’s instruction. A WARNING: under no circumstances should you alter the dosage of any drug prescribed by your doctor! 6 3. Accurate measurement of blood pressure may be difficult in people with serious arteriosclerosis, weak pulse, or in patients with irregular heart rates. Please consult a qualified physician to interpret your blood pressure readings. 4. Keep quiet and relax during measurement. To obtain accurate readings, wait one hour after a meal or smoking before taking a measurement. 5. Wait at least 5 minutes before taking the next measurement. Patients with atherosclerosis or diabetes require longer intervals (10-15 minutes), since vessel elasticity may have decreased in these pathologies. 6. This device is supplied with a standard cuff which accommodates arm sizes of 9-14 inch circumference. Note: DO NOT use a cuff other than the original cuff contained in this kit. 5 BATTERY INSTALLATION 1. Open the battery cover and install four alkaline AA batteries in the battery compartment as indicated. Check polarity and ensure the batteries are correctly positioned; 2. Close the battery compartment cover. • Replace the batteries when the battery replacement indicator “ (=□ ” displays or when the device does not turn on when button “0/1 ” is pressed; • Use only alkaline AA batteries, do not use rechargeable batteries; • Use only same-age, same-type batteries together. Replace all batteries simultaneously; • If the device is to be unused for long time, take out the batteries and store in a dry environment; • Do not leave uncharged batteries in the device. 7 6 using the device with the included ac power adapter Fig. 6-1 Instead of batteries, the included AC power adapter can be used as the power supply. The AC power connector is located on the right side of the device as shown in Fig. 6-1. 8 7 SETTING THE DATE AND TIME The Date and Time function creates the ability to document the date and time each measurement is taken. This device has a 12-hour time format. The icon “AM” indicates the time of Ante Meridiem and the icon “PM” indicat...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien