Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Honeywell, modell 69-1490

Hersteller: Honeywell
Dateigröße: 155.12 kb
Dateiname: 0eff3425-405d-4f9a-b4fb-90ea6fccd3de.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Em Ht Aux Ht Set Room 69-1490 Congratulations on the purchase of your new thermostat! Over 100 years of Honeywell engineering expertise went into the making of this thermostat in an effort to provide you with a more comfortable and convenient living environment. Congratulations on the purchase of your new thermostat! Over 100 years of Honeywell engineering expertise went into the making of this thermostat in an effort to provide you with a more comfortable and convenient living environment. Simple and easy to use. The ^ and Ў keys make it easy for you to change your temperature setting. • Large digital display.You can easily read the current room temperature at a glance. • No need for batteries.Batteries are not required because your temperature settings are held permanently in memory. 69-1490 2 Settings Settings Fan and system settings are controlled by using FAN and SYSTEM switches located on the bottom of the thermostat case. First set the FAN switch: Auto: Normal setting for most homes. In cooling, the fan goes off and on with the cooling equipment. In heating, the fan may start a few minutes after the heating equipment comes on. On: The fan runs continuously. Use for improved air circulation and air quality. FAN Auto On FAN SWITCH M10273 3 69-1490 Then set the SYSTEM switch: Then set the SYSTEM switch: : Normal setting for months when your home needs cooling (air conditioning). Digital display shows a snowflake when cooling is on. Off: Both heating and cooling are off. Heat: Normal setting for months when your home needs heating. Digital display shows a flame when heating is on. Em. Ht.: (Not available on all models.) Switch to this setting when your home needs heat, but your equipment has failed or is not working properly. SYSTEM Cool Off Heat Em.Ht. SYSTEM SWITCH M10274 69-1490 4 Em Ht and Aux Ht Indications Em Ht and Aux Ht Indications active. Em Ht: Aux Ht: The ^ indicator points to Em Ht when the SYSTEM switch is set at Em Ht. The ^ indicator points to Aux Ht when the living space needs auxiliary backup heat to help handle the heating load. INDICATOR Em Ht Set Room M18425 5 69-1490 Displaying Temperature Setting Displaying Temperature Setting : Your temperature setting can be set anywhere from 40° to 99°F (5° to 37°C). The temperature setting and the room temperature are shown separately on the digital display. The Ў indicator points to Set when the temperature setting is displayed and to Room when the room temperature is displayed. 1. To display the temperature setting on the digital display, press either the ^ or Ў key once. Set Room INDICATOR M18441 69-1490 6 Changing Temperature Setting Changing Temperature Setting . To lower the temperature setting, press the Ў key. When in the heating mode, lowering the temperature at night or during the day can lower your energy costs. Set Room M18442 2. To raise the temperature setting, press the ^ key. When in the cooling mode, raising the temperature before you leave for work or school also lowers your energy costs. Set Room M18443 7 69-1490 Energy Savings Energy Savings Savings can be as high as 7% to 33% depending on your home, where you live, the number of energy saving periods you choose and your energy savings temperature settings. If you like saving energy, but would like your thermostat to automatically change the temperature setting, you might want to consider purchasing the Honeywell Chronotherm® Programmable Thermostat. With this thermostat, temperature settings can be conveniently programmed to automatically save energy. 69-1490 8 SAVE 7% TO 33% ON ENERGY COSTS SAVE 7% TO 33% ON ENERGY COSTS SAVINGS FOR ONCE-A-DAY SAVINGS FOR TWICE-A-DAY 10°F (5°C) DECREASE* 10°F (5°C) DECREASE* HEAT 6TO 8% 12 TO 16% 9TO 11% 18 TO 22% 12 TO 13% 23 TO 25% 14 TO 15% 25 TO 29% 16 TO 18% UP TO 30% PERCENT OF COOLING COSTS YOU CAN SAVE SAVINGS FOR ONCE-A-DAY SAVINGS FOR TWICE-A-DAY 10°F (5°C) INCREASE* 10°F (5°C) INCREASE* COOL 7TO 9% 11 TO 15% 10 TO 11% 16 TO 18% 12 TO 14% 19 TO 22% 14 TO 19% 23 TO 33% YOUR SAVINGS DEPENDS ON HOME SIZE AND ACTUAL HEAT LOSS OR GAIN, GEOGRAPHIC LOCATION, FREQUENCY OF TEMPERATURES CHANGE, AND RANGE IN DEGREES OF CHANGE. M10278 * 9 69-1490 Troubleshooting Guide Troubleshooting Guide CAUTION To avoid possible equipment damage, do not operate cooling when outside temperature is below 50°F (10°C). See equipment manufacturer instructions. Heating or cooling does not come on. Temperature setting is too warm or cool. • Check that the SYSTEM switch on the thermostat is set to Heat or Cool. • Check the system fuse or circuit breaker and replace or reset if necessary. • Check for air movement at the register. • Check power to the heating or cooling equipment. • Adjust the temperature by pressing either the ^ or Ў key. 69-1490 10 If you have questions concerning this thermostat, call Honeywell Customer Assistance at 1-800-468-1502, Monday-Friday, 7:00 am-5:30 pm, Central time. If you have questions concerning this thermostat, call Honeywell Cus...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien