Login:
Stimmen - 5, Durchschnittliche Bewertung: 4 ( )

Anleitung Honeywell, modell 43153

Hersteller: Honeywell
Dateigröße: 219.31 kb
Dateiname: 43153.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


n After labeling wires, disconnect them from the existing thermostat terminals. n Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall. n If hole in wall is larger than necessary for wires, seal this hole with insulating material so that no hot or cold air can enter the back of the thermostat from the wall. This air could cause a false thermostat reading. Table A NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non-battery powered thermostats. Mount Wallplate and Thermostat n Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2. n Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided, if your existing holes do not line up with those on the Hunter wallplate. n Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall. n Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. See Figure 3. NOTE: 5-wire Systems If your thermostat has one wire marked R or RH (2, 3, or 4-wire system), then leave the jumper wire between the RH and RC terminals on the wallplate. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals. Connect Wires and Mount Thermostat to Wallplate n Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not connected to the old thermostat. n Refer to the Wiring Diagrams below to be sure your system is wired correctly. n Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with your system or thermostat. n Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate. n Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO. n Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate. Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. (NOTE: Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.) n Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment. n Switch on the main power at the panel or furnace. Wiring Diagrams PROGRAMMABLE THERMOSTAT Owners Manual Model 43153 ! LCD Display: Shows Time, Day, Temperature, Program Number, and other feature information as required. Low Battery Indicator: Flashes when batteries need to be replaced. INDIGLO® night-light: Backlights display automatically with each key press for easy viewing. Up and Down Keys: Keys for changing the Temperature setting. Also used for increasing and decreasing selections in the Time, Program, and Span functions. Day/Time Key: Used for entering the Clock setting mode. Use with the Up and Down keys to set the time and day. Program Key: Used for entering and modifying Programs. Use with the Up and Down keys to set times and temperatures. Press when in Clock setting mode to select between 12 and 24 hour clock modes. Hold / Return Key: Used for setting a permanent (vacation) hold, and for returning to the normal display from Day & Time setting, Programming, or Span setting modes. Reset: Press with a paper clip to reset the thermostat and return to power-up settings. System Switch: Selector switch for Heat, Cool, and Off. Fan Switch: Fan switch for Automatic or Continuous fan operation. Battery Compartment: Front access allows easy insertion of two AA 1.5V batteries. Front Door: Covers keys when not used for neat appearance. Open with one finger from either side. If the code letter on your existing thermostat is then mark the wire with label shown and connect to thermostat terminal shown ® M AM 4 TEMP Air Purifiers Thermostat Guards Humidifiers W G Y RH RC RH G RC Y W x RH x RC x G x Y x W RH, R, VR or 4 24 Volt G or F Fan RC, VC 24 Volt Cool Y, C or M Air Conditioning Compressor W or H Heating Figure 2 Wallplate Terminals G Rc Y1 Y/O W/B Fan Relay Heat Relay or Valve Cool Contactor Heat/Cool 2 4V Supply Rh Jumper X X Wallplate Terminals G Rc Y1 Y/O W/B Cool 24V Supply Fan Relay Heat Relay or Valve Cool Contactor Heat 24V S upply Rh No Jumper X 4-wire Heat/Cool System 5-wire Heat/Cool System Wallplate Terminals G Rc Y W Heat Relay or Valve Heat 24V or M illivolt Supply Rh Jumper X X X 2-wire Heat Only System Wallplate Terminals G Rc Y W Fan Relay Heat Relay or Valve Heat 24V S upply Rh Jumper X X 3-wire Heat Only System Wallplate Terminals G Rc Y W Fan Relay Cool 24V Supply Cool Contactor Rh Jumper X X 3-wire Coo...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - 43153 (219.31 kb)
Steuerungen & Regelgeräte - 43153 (219.31 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien