Anleitung Zusammenfassung


remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged. See page 8 for common examples.) 3. locate, but do not disconnect the wires. (If wires are not visible, they may be connected to the back of the wall plate. Some models may have doors that open to expose the wires and mounting screws.) WIrE lABElS if your existing thermostat label the wire with is marked... this sticker: RH / R / VR / 4 24 Volt RH RH RC / VC 24 Volt cool RC RC air conditioning Y / C* / M / O compressor Y/0 Y/0 G / F W / H / B Y1 heating fan heat pump compressor G G W/B W/B Y1 Y1 UnInSTAllInG THE ExISTInG UnIT, COnT. 4. Using the provided stickers, label each wire according to the Wire labels chart. (If the terminals are not labeled, contact a qualified HVAC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. refer to the existing terminal designation for proper identification. *If wires marked Y & C are both present, C may be a Common wire and should not be used. If you have a wire marked C, do not connect it to any terminal. This wire is used only for non-battery powered thermostats. 5. Do not let the wires slip back into the wall during disconnection. You may want to secure the wires to the wall as you disconnect them. After all wires are labeled, disconnect each wire and remove the existing wall plate. (Any unused wires should be capped with an approved electrical connector, such as electrical tape.) 12 W/BRCGY/ 0Y1W/BRCGY/ 0Y1 12 InSTAllInG THE THErMOSTAT InSTAllInG THE WAll PlATE 1. remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 14 WRCYG WRCYG InSTAllInG THE THErMOSTAT, COnT. 4. remove the wall plate and drill two 3/16” holes where marked. 5. Tap the plastic anchors into the holes until they are flush with the wall. (Do not use plastic anchors if you encounter a stud in the wall.) 6. reposition the wall plate on the wall, pulling the wires through the opening. Insert the mounting screws through the wall plate and into the anchors. Verify that the wall plate is visually level and securely tighten both screws. 16 GRCRHY/0W/BRCGY1Y/0W/BY1Terminal Shield GRCRHY/0W/BRCGY1Y/0W/BY1Terminal Shield 17 InSTAllInG THE THErMOSTAT, COnT. COnnECTInG THE WIrES 1. loosen, but do not remove, the terminal screws. note: A jumper wire has been provided, connecting the rC and rH terminals for systems that do not provide both an rH and rC wire. If you have both an rH and rC wire, remove this jumper. If you do not have both an rH and rC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted behind the black terminal shields. Tighten each screw after the connection has been made. (The ends of any extra wires should be individually wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interference. GRCRHYWJumper InSTAllInG THE THErMOSTAT, COnT. COnnECTInG THE WIrES 1. loosen, but do not remove, the terminal screws. note: A jumper wire has been provided, connecting the rC and rH terminals for systems that do not provide both an rH and rC wire. If you have both an rH and rC wire, remove this jumper. If you do not have both an rH and rC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted behind the black terminal shields. Tighten each screw after the connection has been made. (The ends of any extra wires should be individually wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interferen...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - 42710-01 (2.41 mb)
Steuerungen & Regelgeräte - 42710-01 (2.41 mb)
Steuerungen & Regelgeräte - 44360 (2.41 mb)
Steuerungen & Regelgeräte - 42710-01 (2.41 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien