Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Hunter Fan, modell RC-80BZ

Hersteller: Hunter Fan
Dateigröße: 248.24 kb
Dateiname: RCI80BZ.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


When used with remote systems, HAI recommends that the thermostat be configured as "nonprogrammable" (See Setup Item 03 - "Display Options"). HAI AUTOMATION SYSTEMS The thermostat can communicate with an HAI automation system over a Z-Wave network. The controller can send commands to the thermostat to change mode, cool setting, heat setting, status of fan and hold, and other items. ADDING A THERMOSTAT TO THE Z-WAVE NETWORK When prompted by Z-Wave primary or inclusion controller to include the thermostat to the network, press and release the ‘Hold’ button on the thermostat. This will include the thermostat on the Z-Wave network. REMOVING A THERMOSTAT FROM THE Z-WAVE NETWORK When prompted by Z-Wave primary or inclusion controller to exclude the thermostat from the network, press and release the ‘Hold’ button on the thermostat. This will exclude the thermostat from the Z-Wave network. The thermostat supports the following command classes: COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_SETPOINT COMMAND_CLASS_THERMOSTAT_FAN_MODE COMMAND_CLASS_THERMOSTAT_FAN_STATE COMMAND_CLASS_THERMOSTAT_OPERATING_STATE COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_CLOCK COMMAND_CLASS_THERMOSTAT_MODE Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can set the mode, get the current mode, and get the modes supported by the thermostat. COMMAND_CLASS_THERMOSTAT_SETPOINT Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can change setpoints, get current setpoints, and request the setpoints that are supported by thermostat. COMMAND_CLASS_SENSOR_MULTILEVEL The RC-80BZ thermostat uses this command class to report the actual temperature. COMMAND_CLASS_ASSOCIATION Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can issue an Association Set, Remove, or Get command. The thermostat must be associated with a controller to provide feedback. COMMAND_CLASS_CONFIGURATION Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can change individual register settings for the outdoor temperature. The Parameter Number is 67. The size of the data is a 1 byte value. The Value is the temperature to which the register is set. COMMAND_CLASS_THERMOSTAT_FAN_MODE Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can set the fan mode, get the current fan mode, and get the fan modes supported by the thermostat. COMMAND_CLASS_THERMOSTAT_FAN_STATE Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can request the state of the fan. COMMAND_CLASS_THERMOSTAT_OPERATING_STATE Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can request the Operating State report. COMMAND_CLASS_VERSION Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can request a Version Report. This report includes information about the library type, protocol, version, and application version from the device. COMMAND_CLASS_MANUFACTURER_SPECIFIC Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can request a Manufacturer Specific Info Report. This report will return the Manufacturer ID, Product Type, and Product ID. COMMAND_CLASS_SWITCH_BINARY Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can turn on the Hold feature by sending a Binary Switch On command and turn off the Hold feature by sending a Binary Switch Off command. COMMAND_CLASS_CLOCK Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controller can set the time of the internal clock INTEROPERABILITY WITH Z-WAVE™ DEVICES A Z-Wave™ network can integrate devices of various classes, and these devices can be made by different manufacturers. The RC-80BZ thermostat can be incorporated into existing Z-Wave™ networks. All listening Z-Wave nodes act as repeaters regardless of vendor. FCC NOTICE Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which c...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - RC-80BZ (248.24 kb)
Steuerungen & Regelgeräte - RC-80BZ (248.24 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien