Hersteller: Hunter Fan
Dateigröße: 1.34 mb
Dateiname: 83d348f0-af1e-4d2d-b329-4d5feb74cdd8.pdf
|
Anleitung Zusammenfassung
With the STAGE TIMER (Option 10) set to 0, stages 2 and 3 will be controlled by the SPAN setting only. If the stage timer is set to 30, the system will turn on the next stage based on the SPAN setting or 30 minutes, which ever comes first. Span settings remain the same for Heating and Cooling. 44002-01 r051807 SYSTEM SETTINGS MENU The installer can set SYSTEM functions once the thermostat is installed. The default settings are shown in bold in the following list. Options are listed inside the parentheses. Example: the default SYSTEM TYPE is CONVENTIONAL with (HEAT PUMP) as a second option. See pages 28-29 to change these settings. 1. SYSTEM: CONVENTIONAL (CONVENTIONAL, HEAT PUMP) 2. FURNACE TYPE: GAS/OIL (GAS/OIL, ELECTRIC) 3. STAGE ONE SPAN (defined on page 26): 2F (1F, 2F, 3F) 4. STAGE TWO SPAN (not available on 1H/1C models): 2F (2F, 3F, 4F, 5F, 6F) 5. AUTO SEASON SPAN: 5F (3F, 4F, 5F, 6F) 6. TEMPERATURE CALIBRATION: 0F (-2, -1, 0, +1, +2) 7. STAGE TIMER: 0 minutes (0, 30) 8. RESIDUAL COOLING TIMER: 30 seconds (0, 30, 60, 90) 9. RESTORE FACTORY SETTINGS: NO (YES, NO) 44002-01 r051807 SYSTEM SETTINGS MENU (CONT'D) SYSTEM or USER13456278 44002-01 r051807 1. Touch a blank area of the touch screen. 2. Press and hold for 3 seconds for SYSTEM and USER settings to appear. 3. Touch SYSTEM. The selected word flashes. 4. Touch . 5. Scroll through the first setting with the or sign to select an option. Refer to the list on page 27 for setting options. 6. Touch to confirm selection and move to next setting. 7. When all settings are complete, touch to exit. 8. Touch to return to the main screen. 44002-01 r051807 USER SETTINGS The PERIODS PER DAY (Option 1) can be set to 0, 2 or 4. When set to 0, the thermostat operates as a digital non-programmable thermostat. The FILTER CHANGE INDICATOR (Option 2) runs in calendar days and can be set from 30-360 days in 15-day increments (the default is 90). The REFRESH FAN ON (Option 3) function runs only the fan during heating or cooling off cycles. This balances the indoor air and improves air quality by cycling the air through the filter. 44002-01 r051807 USER SETTINGS MENU The USER can also set certain functions in the USER SETTINGS MENU. The default settings are shown in bold in the following list. Options are listed inside the parentheses. Example: the default PROGRAMS PER DAY is 4 Periods with (0 and 2) as options. See pages 32-33 to change these settings. 1. PROGRAMS PER DAY: 4 Periods (0, 2, 4) 2. FILTER CHANGE DAYS: 90 Days (30-360, in 15 day increments) 3. REFRESH FAN ON TIME: 15 Minutes (10, 15, 20, 30) 4. CLOCK DISPLAY: ON (ON, OFF) 5. DAYLIGHT SAVING: ON (ON, OFF) 6. TOUCHPAD BUZZER: ON (ON, OFF) 7. TEMP SCALE: F (Fahrenheit, Celsius) 8. LCD CONTRAST: 5 (0-9) 44002-01 r051807 USER SETTINGS MENU (cont'd) SYSTEM or USER13527468 44002-01 r051807 1. Touch a blank area of the touch screen. 2. Press and hold for 3 seconds for SYSTEM and USER settings to appear. 3. Touch USER. The selected word flashes. 4. Touch . 5. Scroll through the first setting with the or sign to select an option. Refer to the list on page 31 for setting options. 6. Touch to confirm selection and move to next setting. 7. When all settings are complete, touch to exit. 8. Touch to return to the main screen. 44002-01 r051807 TEMPERATURE RANGE This thermostat meets ENERGY STAR guidelines for energy efficiency. By using the preprogrammed and default settings, this thermostat can save you money by optimizing energy usage in heating and cooling. Display Range30o F 99o F (0o C)(37o C) 45o F Program Range95o F (7o C) (35o C) Out of Range"HI" >99o FOut of Range"LO" <30o F 44002-01 r051807 ENERGY STAR DEFAULT PROGRAMS Refer to the Energy Star Default Programs Chart shown below for detailed Information about pre-programmed settings. If customizing your programs, you can revert to the Energy Star default programs below by pressing the icon in the program mode. 10 pm8 am6 amProgram 1Heat : 68o F (20o C) Cool : 78o F (26o C) Program 2Heat : 60o F (16o C) Cool : 85o F (29o C) Program 3Heat : 68o F (20o C) Cool : 78o F (26o C) Program 4Heat : 60o F (16o C) Cool : 82o F (28oC) 4 pm 44002-01 r051807 MANUAL OPERATION Many people prefer to operate their thermostats manually, adjusting settings as needed. NOTE: PROGRAMS PER DAY must be set to 0 for manual operation. See USER SETTINGS MENU (pages 31-33). SET HEAT OR AC SYSTEM MODE MAY 17 2006THURSDAY1234567 44002-01 r051807 1. Touch a blank area of the touch screen. SELECT FUNCTION appears. 2. Touch the or icon. SET SYSTEM MODE appears. 3. Scroll through the settings with the or sign to select one of the SYSTEM modes: HEAT ( icon, red screen) EMHEAT (only for Heat Pump Systems) AUTO ( and icons) COOL ( icon, blue screen) OFF (no icon) 4. Touch to return to the main screen. The icon will show on the main screen if the system is heating; the icon will show if the system is cooling. NOTE: If the system is running and the or icon is touched on the main screen, it will return you...
Dieses Handbuch ist für folgende Modelle:Steuerungen & Regelgeräte - 144860 (1.34 mb)
Steuerungen & Regelgeräte - 144860 (1.34 mb)